Design and Function
Attention!
Hazards must be ruled out before a key can be entered and
!
the movable part of the guard can then be opened!
Optionally, another key can be removed. The STS/K solenoid locking unit
is to be integrated into a system and connected with a control unit so that
the hazardous machine can run only when the guard is locked and closed.
After entering a first key into key module 10/K the actuator can be removed
from actuator module B/K and the access can thus be opened. The first
key is blocked and the second key released after removing the actuator.
The actuator is blocked when the second key is removed from key module
01/K. This ensures an escape route. Only after the second key and the
actuator (access is locked) were returned to their starting position can the
first key be removed again and the solenoid locking is activated.
Mechanical guard locks are in the system in connection with additional
STS/K units and SAFEMASTER products. The first key to be entered
mayoriginatefromtheseunits(e.g.releasethroughupstreamsolenoidlocking
ZRH01A/K in connection with a speed monitor UH 5947 or standstill monitor
LH 5946). The second key, optionally to be removed, can serve as
protection against lock-in or for the operating release of additional units
(e.g. M10BM/K, M11BM/K, M12M/K, M10B01M/K).
20
SAFEMASTER STS/K-M10B01M/K / 11.01.21 en / 335A