Safety Technique
SAFEMASTER STS/K
Safety Switch- and Key Interlock System
Basic Unit M10B01M/K
Presentation in the deactivated condition:
1st key inserted; Actuator and 2nd key removed
Product description
Mechanical guard locking with separate actuator and optional key removal
To secure separating guards such as safety gates and hoods in machine
and plant engineering. After inserting the first key, the actuator must be
removed so that the second key is released.
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
STS/K-System Benefits
• EU-Test certificate according to the directive 2006/42/EG, annex IX
• For safety applications up to PLe / Cat. 4 acc. to DIN EN ISO 13849-1
• Modular and expandable system
• Rugged composite version of stainless steel and FRP design
• Wireless mechanical safeguarding
• Combines the benefits of safety switch, solenoid locking and
key transfer in a single system
• Easy installation through comprehensive accessories
• Protection against lock-in
• Coding level low, medium, high according to DIN EN ISO 14119:2014-03
Features
• The unit is particularly suitable for applications with:
• Full body access (lock-in danger)
• Optional key removal
• Several secured entries
• Rugged ambient conditions
• This unit is also available in stainless steel
Approvals and Markings
Function
The M10B01M/K unit is available with low and medium coding levels
according to EN ISO14119:2013.
The second key can be used as part of a key transfer system or as a
personal key, i.e. as protection against confinement and unexpected
restart. Multiple keys allow the operation of several units in the system or
the protection of several people. The M10B01M/K unit can be expanded
with additional key modules both below and above the actuator module.
The use of personal keys normally eliminates the need for an escape
release (ISO TS19837:2018).
Optionally, this unit can be equipped with padlock modules, electrical
monitoring contacts or an electromechanical release.
19
SAFEMASTER STS/K-M10B01M/K / 11.01.21 en / 335A
C
US