ELPRO 37 DB
GB
ELECTRONIC BRAKE FUNCTION
To enable the electronic brake function set the dip-switch - B n. 8 n ON and adjust the electronic brake
intensity by means of the the selector in the figure.
The factory preset adjustments are suitable for most installations.
For a more precise regulation of the electronic brake, it is possible to set up various braking
parameters by following the advanced instructions bellow.
ADVANCED INSTRUCTIONS FOR THE ELECTRONIC BRAKE
ATTENTION: the electronic brake is to be enabled by putting the dip-switch B No.8 in ON.
Function
Braking time:
To adjust the braking duration it is necessary to put the dip-switch B
No. 1 in ON and set the braking time by Trimmer T.FUN.
Once the calibration of braking duration is completed, put all
dip-switches B in OFF.
Additional stop
To set the additional stop time after braking it is necessary to put the
time after braking
dip-switch B No. 2 in ON and adjust the stop time by mean of
trimmer T.FUN.
when safety
Once the calibration of additional stop time is completed put all
devices are
dip-switches B in OFF.
activated:
N.W.: this function is enabled and adjustable even if the
electronic brake is disabled. It allows more time for the gate to
reverse the travel direction when safety devices as photocells or
sensitive edges are engaged, so as proper reverse movement is
achieved, especially for single-phase motors where high inertia is
involved.
For setting working time of the electric lock or courtesy lamp
Electric lock:
connected to the 14-15 outputs, put the dip-switch B No. 3 in ON
and adjust the working time by mean of trimmer T.FUN.
In this mode, the trimmer T.FUN enables you adjust electric lock
working time from 0 s to 5 s in the first half of trimmer travel. In the
second half of trimmer travel it allows you connect a relay to 14-15
or courtesy lamp:
outputs for a courtesy lamp working time control, adjustable from
30 s to 5 min.
Once the electric lock or courtesy lamp working time is set, put all
dip-switches B in OFF.
UNIVERSAL ELECTRONIC CONTROL BOX SINGLE-
THREE-PHASE 230/400 V - 50/60 Hz
Description
Description
12 Vac power supply output
14 15
for electric lock 15 VA max
or relè for courtesy lamp control
DIP-SWITCH - B
ON
OFF
DIP-SWITCH - B
ON
OFF
DIP-SWITCH - B
ON
OFF
17
Dip - switch and trimmer of functions
DIP-SWITCH - B
ON
OFF
1 2 3 4 5 6 7
8
1 2
3
4 5
ELECTRONIC BRAKE
INTENSITY
Dip - switch and trimmer of functions
Operations
I
II
T.FUN
0s - 2s
OFF
1
2 3 4
Operations
I
II
T.FUN
0s - 3s
OFF
1
2 3 4
Operations
I
II
T.FUN
5s
30s
OFF
1
2 3 4
0s
5min
III
DIP-SWITCH - B
ON
1 2 3 4
III
DIP-SWITCH - B
ON
1 2 3 4
III
DIP-SWITCH - B
ON
1 2 3 4

Publicité