ELPRO 37 DB
GB
Dip-switch A
1 = ON photocells stop gate in opening
2 = ON radio, no reversing in opening
3 = ON automatic closing
4 = ON pre-flashing in service
5 = ON radio step-by-step
6 = ON traffic lights mode limit switches connected
Dip-switch B
1 = ON set braking duration
2 = ON set additional stop time after braking when safety devices are activated
3 = ON set electric lock or courtesy lamp duration
4 = OFF blank
5 = ON traffic lights "yellow" for 3 seconds
6 = ON DSA control by photocell transmitters if connected to the dedicated terminals
7 = ON hold-on-switched (deadman) control
8 = ON electronic brake enabled
Accessory
nd
2
pair photocells
(fitted inside perimeter):
st
1
pair photocells
(fitted outside perimeter):
Key-switch:
Radio contact
(step by step mode):
Indication lamp output
24 V max 3 W:
UNIVERSAL ELECTRONIC CONTROL BOX SINGLE-
THREE-PHASE 230/400 V - 50/60 Hz
7 = ON stroke reversing pulse in opening cycle
8 = ON no gate delay in opening, motors start together
nd
9 = ON 2
pair photocells in service
10 = ON flasher off in dwell time
11 = ON gate re-closing in opening and dwell on engaging the photocells
12 = ON memory of motor run time settings enabled,
with installations where very frequent operations are required
Electrical connections
This pair of photocells stops gate in opening; once
cleared from obstacle, gate goes on opening, gate
travel is reversed in closing.
32
35
Dip-A n° 9 = ON and the NC contact connected:
the gates stay stopped as long as the photocells
NC
are obstructed.
- In opening cycle: obstacle removed, gates go on
opening
NC
- In closing cycle: obstacle removed, gate travel
reversed
NOTE: if no 2
not necessary to bridge the contact input, only
dip-A n° 9 = OFF
1
2
NC
NC
All of the NC contacts of the safety
accessories such as the photocells
(receivers)
are
to
be
connected to terminals 1 and 2
NO and NC contacts to be connected
3
4 5 6
to the respective terminals in the key-
or button-switches. All of the possible
setting combinations are described in
the instructions sheets included with
NC
the respective control accessories
Any NO connection to these two terminals
3
7
will perform the following:
- Opening only: dip 2 = ON and dip 5 = OFF
- Gate travel reversing by any pulse
dip 2 = OFF and dip 5 = OFF
- Step by step: open-stop-close-stop
dip 2 = OFF and dip 5 = ON
- No new pulse is accepted in opening.
In Dwell phase and in closing any new
RADIO
pulse stops and reverses gate travel:
CONTACT
dip 2 = ON and dip 5 = ON
Output for a 24 V max 3 W indication lamp showing the status of the system:
3
11
Lamp ON = gate open
Lamp OFF = gate closed
0,5 s (fast) flashing = gate closing
1 s (normal) flashing = gate opening
nd
pair photocells are used, it is
12 13
24 Vac output max load:
n° 1 radio receiver
n° 3 pairs photocells
series
12
DIP-SWITCH - A
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - B
ON
OFF
1 2 3 4
5 6 7 8
Dip-switch setting and LED indication of functions
DIP-SWITCH - A N° 9:
nd
ON: Photocells 2
pair in service
9
nd
OFF: Photocells 2
pair not installed
L35 ON = no obstacle detected,
it goes off in case of obstacle
DIP-SWITCH - A N° 1:
ON: stop gate/s in opening and reverse travel
in closing when cleared
OFF: no stop in opening and reverse travel
1
in closing when obstructed
L1 ON = no obstacle detected,
it goes off in case of obstacle
L4 OFF = no OPENING contact,
it goes on whenever an opening pulse is given
L5 OFF = no CLOSING contact,
it goes on whenever a closing pulse is given
L6 ON = STOP contact closed,
it goes off whenever a stop pulse is given
DIP-SWITCH - A N° 2 and N° 5:
ON: it does not stop and reverse gate travel
in opening
2
OFF: always stops & reverses in opening
ON: step by step with intermediate stop
5
OFF: gate travel reversed by any radio pulse
L7 OFF = no RADIO contact,
it goes on by any radio pulse