ELPRO 37 DB
GB
AUTOMATIC / SEMI-AUTOMATIC:
Automatic cycle: by one pulse from the open command the gate opens and stops in dwell mode
for the time as pre-set on the dwell trimmer. When this time expires the gate closes automatically.
Semi-automatic cycle: by one pulse from the open command the gate opens and stopsin fully
open position. To close the gate, a close pulse is needed.
PEDESTRIAN OPENING ONLY FOR MOTOR M1:
With the gate in fully closed position, a pulse to terminals P-P
operates the gate for pedestrians.
(On pedestrian mode, it is advisable to set dip-A n° 3 = ON for
automatic re-closing).
The function pedestrian opening is not in service during the first
operation cycle, after a power failure.
RE-CLOSING BY PASSING ACROSS THE PHOTOCELLS:
in opening and dwell cycles (DIP-A N° 3 = ON)
Gate is automatically closed after 3 s from passing between the photocells.
In case a second pair of photocells are installed, (dip-9 = ON), both pairs are to bepassed across.
DSA:
PHOTOCELL AUTOMATIC CONTROL
For the DSA control (Device for Safety Auto-test) it is necessary to connect only
the photocell transmitters (TX) to this output and select dip-B n° 6 = ON: if this
function is enabled, Elpro 37 DB checks that all the connected photocell devices
are cleared from obstacles and properly working before starting any door/gate
movements, otherwise the door/gate is not started.
DEADMAN (HOLD-ON-SWITCHED) FUNCTION:
The open/close operations are achieved by holding on a command switched (the relays are not
self-holding) and consequently the user must be actively present during gate movements until
the push-button or the key-switch is released.
STROKE REVERSING PULSE IN OPENING CYCLE:
This function helps the gate electric lock to release with the gate/s in fully closed position, even
in pedestrians mode: the gates in closed position are pushed to close direction for 2 seconds
before the opening cycle begins.
APPLICATIONS IN BLOCKS OF FLATS:
This is a function for heavy duty applications with frequent inversions of direction: this function,
when enabled, takes into account the remaining motor run time when there is an inversion of
direction or passage between the photocells.
PARTY FUNCTION
OPEN-AND-HOLD BY EXTERNAL CLOCK:
Connection: connect the clock NO contact to OPEN
terminals n° 4 and COMMON n° 3, and activate
automatic closing by dip-switch n° 3 = ON.
How it works: program the opening time on the clock.
At the preset time, the gate will open and remain open
(the flashing light will turn off ) and will not accept any
other command (not even radio commands) until the
time set on the clock expires.
When this time expires the gate closes automatically
after the pause time. While the gate is held open by the
time set on the clock, the indication light keeps giving
out two consecutive flashes followed by a long pause.
UNIVERSAL ELECTRONIC CONTROL BOX SINGLE-
THREE-PHASE 230/400 V - 50/60 Hz
Description
3 4
Dip-switch setting and LED indication of functions
DIP-SWITCH - A N° 3:
3
DIP-SWITCH - A N° 9 and N° 11:
9
11
DIP-SWITCH - B N° 6:
38 39
6
DIP-SWITCH - B N° 7:
7
DIP-SWITCH - A N° 7:
7
DIP-SWITCH - A N° 12:
12
DIP-SWITCH - A N° 3:
External clock
3
IMPORTANT:
use always and only with dip-A N° 3 = ON
NO
16
ON: automatic closing
OFF: semi-automatic
Dwell trimmer: adjust dwell time on
automatic mode from 1 s up to 220 s
L0 OFF = no pedestrian contact given,
it goes on by pulsing for pedestrians
1 2 3 4 5 6
OPEN
PEDESTRIANS
ON: 2
nd
pair photocells enabled
nd
OFF: 2
pair photocells not installed
ON: automatic closing on passing across
the photocells after 3 seconds
OFF: no automatic closing on passing across
the photocells after 3 seconds
ON: DSA safety control enabled
OFF: DSA safety control disabled
ON: deadman control enabled
OFF: deadman control disabled
ON: stroke reversing pulse in opening enabled
for 2 s
OFF: no stroke reversing pulse
ON: memory of motor run time settings enabled
OFF: no memory enabled
ON: automatic closing