Télécharger Imprimer la page

King gates DYNAMOSXL 2500-I Consignes Pour L'installation Et L'utilisation page 33

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 56
2 - TECHNICAL DATA
Gate maximum weight
Power supply
Maximum power
Idling current
Full load current
Gate maximum speed
Maximum thrust
Duty cicle
Pinion
Operation temperature
Weight
Protection
Maximum load on 24 VAC attachments
Protection fuses
WARNING: The following chart indicates the recommended maximum speed that can be programmed (via the
depending on door weight.
m
WARNING – DO NOT EXCEED THE INDICATED MAXIMUM SPEED
40,00
35,00
30,00
25,00
20,00
15,00
10,00
DYNAMOS 2500-I
2500 Kg
230VAC / 50Hz
650 W
0,5 A
3,7 A
0,035 ÷ 0,35 m/s
1660 N
50%
M4 - Z18
-20°C ÷ +55°C
19 Kg
IP44
10W
F1 = 8A
vEL
Parameter)
Gate weight [kg]
ENGLISH - 31 -

Publicité

loading