CAUTION: At least two installers are
required due to the weight and size of the
hood.
2. Plum and mark center line.
tighten all the way. Note: Wood blocking may need to be
added behind the drywall if no studs are present. Wall
anchors may also be used but check local codes for
compliance. Failure to use suitable wall anchors and
screws to hold the weight of the hood could result in
personal injury or damage to cooking surface or counter.
bracket to hood. Reposition electronics mounting bracket as
previously removed screws.
9. Hang hood onto the mounting screws and hand tighten each
10. Center and attach duct cover mounting bracket to wall just
11. Install electrical and duct work. Seal duct work with aluminum
duct tape. Re-install electrical junction box with cable lock and
12. Power up hood and check for leaks around duct tape.
M3.5 x 8 screws.
14. Place canopy over hood body and secure it to hood body using
* If using hood in recirculating mode you must secure the air diverter
plate onto wall before installing duct work and duct covers. Turn
to page 10 for more details.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
Cable Lock
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.
11 1/4"
Brackets are
pre-installed
FIG. A
Cable Lock
9
18 5/8"
26" min
1
2
2
1
3
Motor Housing
FIG. B