GB
The following security information is integrant and essential part of the product and must be given to the user. Read it carefully as it gives important sug-
gestions concerning the installation, the use and the maintenance. Keep the present manual in order to be able to transmit it to possible future users of
the installation. The erroneous installation or an improper use of the product may cause great danger.
IMPORTANT - SECURITY INFORMATION
. The installation must be carried out by professional technicians and according to the national and european safety regulations in force.
. After removing the packing check the integrity of the appliance. If in doubt contact qualified personnel.
. The packaging (carton, plastic bags, clips, polystirene etc.) must be disposed of properly in the appropriate containers. It must not be left within the
reach of children.
. The mechanical manufacturing elements must be in accordance with the Norms EN12604 and EN12605
. The installation must be carried out according to the Norms EN12453 and EN12445.
. The security devices, Norm EN12978, allow the protection of dangerous areas against mechanical movement hazards.
. The installation, the electrical connections and the adjustments must be carried out perfectly; check that the data on the specification plate corre-
spond to those of the mains supply and that the connection cable cross-section is suitable for the applied loads, in case of doubt contact qualified
personnel.
. Do not install the appliance in premises with danger of explosion or disturbed by magnetic fields. The presence of gasses or inflammable fumes is a
great danger for the safety.
. A proper protection against extratensions should be install on the supply voltage network, i.e. a switch/sectioner and/or differential suitable for the
product and according to the regulations in force.
. The gate, door, rolling shutter or barrier should bear a plate indicating that they are remotly controlled.
. ELVOX S.p.A. will not accept liability for any damage caused by the incorrect installation of devices and/or components not suitable for the integrity,
the safety and the operation of the unit.
. The product must only be used for the purposes for which it was designed. Any other use is incorrect and hence dangerous.
. Before carrying out any cleaning or maintenance work, disconnect the unit from the mains supply, either by unplugging the power cord or by swit-
ching off the mains supply.
. Any repair work or replacement of damaged parts must be carried out by qualified personnel using original parts and components.
. The installer must supply all the information concerning the operation, the maintenance and the use of the single components and the whole system.
. What is not expressly forseen in these instructions is not allowed.
PACKAGING CHECK-LIST
Articulated gearmotors do not present any particular transportation issues
The packaging used consists of a cardboard box, which should be kept in
a dry place sheltered rom the weather. After having unpacked the actuators,
check that all parts are present, including any accessories supplied. If in
doubt, immediately contact the reseller.
Check at the time of purchase that the product is fitted with the specifica-
tion plate detailing the technical characteristics of the unit. If the plate is
missing, immediately notify the manufacturer and/or supplier.
Units without specification plates must not be used under any circum-
stances. Such use will result in the manufacturer refusing to accept any re-
sponsibility. Products without specification plates are to be considered
anonymous and potentially dangerous.
Packaging contents:
1- Gearmotor complete with arms (not included in the packaging)
1- Fixing plate complete with accessories
1- Release key
1- Condenser (230 V ac)
ATTENTION: The common connecftion wire it's color BLUE or GRAY.
TECHNICAL DATA
Max. wing weight
Max. wing length
Motor power supply
Motor power
Motor rpm
Condenser
Mechanical emergency release mechanism
Operating temperature
Weight
Protection rating
90° opening time
Average motor power consumption
DIMENSIONS
EA32
200 kg
2.50 m
230 V ac
200 W
1400
12.5 μF
With key
-20°C / +55°C
8 kg
IP 44
15 sec
1.2 A
8/32
Fig.1
Fig.2