Check the switch interlock for correct operation.
Motor overload cut-out - All machines are fitted with an
automatic reset motor overload cut-out. The cut-out will
operate to protect the motor from overheating by switching
the machine off when there is excessive friction/resistance to
the cleaning head on the floor. This is usually caused by the
stickiness of the pad or floor. Turn the cleaning pad over or if
both sides are dirty replace with a clean pad. It is not possible
to obtain a good finish on the floor using a dirty pad. Should
the cut-out operate it will reset automatically when the
motor has cooled sufficiently, usually after 15 - 30 mins.
Drive boards, pads and brushes - Inspect for wear and replace
worn brushes. Clean under running water.
AFTER SALES SERVICE
Truvox machines are high quality machines that have been tested
for safety by authorised technicians. It is always apparent that after
longer working periods, electrical and mechanical components will
show signs of wear and tear or ageing. To maintain operational
safety and reliability the following service interval has been defined:
Every year or after 250 hours. Under extreme or specialised
conditions and/or insufficient maintenance, shorter maintenance
intervals are necessary. Use only original Truvox spare parts. Use
of other spare parts will invalidate all warranty and liability claims.
Should you require after sales service please contact the supplier
from whom you purchased the machine, who will arrange service.
Repairs and servicing of Truvox products should only be
performed by trained staff. Improper repairs can cause
considerable danger to the user.
GUARANTEE
Your product is guaranteed for two years from the date of original
purchase, or hire purchase, against defects in materials or
workmanship during manufacture. Within the guarantee period we
RECOMMENDED SPARES & ACCESSORIES
Polypropylene scrubbing brush
Standard drive disc
Solution tank
Furniture guard

FAULT DIAGNOSIS

The following simple checks may be performed by the operator. If the machine is still not working, please contact your local Service Agent:
Trouble
Machine not working, neon
indicator not lit
Machine not working, neon
indicator lit
0
0
0
0
Machine wobbles or vibrates
excessively
0
0
0
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.
PLEASE REFER TO THE BACK OF THE MANUAL FOR PICTORIAL INSTRUCTIONS
3
OB28240
05-4442-0500
05-4441-0500
05-4435-0500
03-8061-0000
Reason
Lack of voltage/electrical supply
Switch interlock incorrectly
operated
Overload cut-out operated
Pad worn or damaged
Dirty pad
Loose pad
Pad is off centre
undertake at our discretion, to repair or replace free of charge to
the purchaser, any part found to be defective, subject to the
following conditions:
CONDITIONS
1.
Claims made under the terms of the guarantee must be
supported by the original invoice/bill of sale issued at the time
of sale, or the machine Serial No.
2.
For claims under this guarantee contact the supplier from
whom you purchased the product who will arrange the
appropriate action. Do not initially return the product as this
could result in transit damage.
3.
Neither Truvox nor its distributor shall be liable for any
incidental or consequential loss.
4.
This guarantee is governed by the laws of England.
5.
This guarantee does not cover any of the following:
Periodic maintenance, and repair or replacement of parts
due to normal wear and tear.
Damage caused by accident, misuse or neglect, or the
fitting of other than genuine Truvox parts.
Defects in other than genuine Truvox parts, or repairs,
modifications or adjustments performed by other than a
Truvox service engineer or authorised service agent.
Costs and risks of transport relating directly or indirectly
to the guarantee of this product.
Consumable items such as belts, brushes, drive discs,
filters and vacuum skirts.
This guarantee does not affect your statutory rights, or your rights
against the supplier arising from their sales or purchase
contract.Truvox International Limited policy is one of continual
product development and we reserve the right to alter
specifications without prior notice.
Remedy
Check fuse *, power cord, plug and socket outlet
Check operating procedures shown in pictorial user guide
Check brush/pad for wear and replace if required
Check correct liquid type and quantity
Wait 30 minutes to allow the motor temperature to reach
room temperature. Then try again.
Replace pad
Clean the pad
Check drive disc for signs of damage
Reposition pad