10.3
flame characteristics
It's important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ame
appears abnormal call a service person.
10.4
optional anti condensation switch (models CB42NTRE and CB42PTRE only)
This appliance has the option to change from an electronic intermittent pilot ignition (IPI) to a standing pilot for cold
climates. The anti condensation control (standing pilot) is located in the center of the control panel. Using your
finger, flip the switch up for standing pilot, or down for intermittent pilot ignition.
Turning the ACS switch on will allow the pilot flame burning to burn continuously. This mode will minimize the
condensation which forms on the inside of the glass when the main burner is first turned on. It will also help the
fireplace and vent system stabilize more quickly during the colder winter months.
During the warmer winter and summer months, the ACS switch can be turned off to minimize fuel consumption.
3/8" - 1/2"
(9.5mm - 12.7mm)
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2"
(12.7mm - 9.5mm) OF
THERMOCOUPLE &
THERMOPILE
MILLIVOLT
ILLUSTRATED
54.2A
W415-1541 / C / 11.23.17
53