_PerfectCharge_IU152A-IU802A.book Seite 49 Dienstag, 15. September 2009 5:19 17
PerfectCharge
Setting the charging voltage for IU152A, IU252A, IU452A and IU802A:
Charging voltage
13.8 V
14.4 V
14.8 V
Setting the charging voltage for IU154A, IU254A and IU404A:
Charging voltage
27.6 V
28.8 V
29.6 V
Setting the duration of the main charging phase:
Duration of the main charging phase
Setting the charging mode:
Charging mode
The trickle charge is activated according to the charging current.
The charging voltage is maintained for the duration of the set main
charging phase irrespective of the charging current. When this time has
passed, the device switches back to trickle charge.
10.2
Switching sleep mode on/off with the remote
control (accessory)
Note
I
When main switch (fig. 2 1, page 3) is in position "II", the remote
control is inactive.
➤ Move the main switch IU0U-automatic loader (fig. 2 1, page 3) to posi-
tion "I", so that sleep mode can be switched on/off via remote control.
➤ To switch sleep mode on/off, press the "ON/OFF" button on the remote
control.
Switch 1
OFF
ON
OFF
Switch 1
OFF
ON
OFF
8 hours
16 hours
Using the IU0U automatic charger
Switch 2
Area of application
OFF
Old starter batteries,
mains adapter operation
OFF
Wet and gel batteries
ON
Fleece batteries
Switch 2
Area of application
OFF
Old starter batteries,
mains adapter operation
OFF
Wet and gel batteries
ON
Fleece batteries
Switch 3
Area of application
ON
Wet batteries
OFF
Gel and fleece batteries
Switch 4
OFF
ON
49