Note:
To prevent shipping damage, the spout is attached to the
2. mm
spout escutcheon with two adhesive strips. Remove the
strips before installing the spout.
Loosen the spout screw with a 2. mm Allen wrench.Pull
the spout away from the escutcheon.
Remove the adhesive strips.
adhesive strips
Reassemble the spout assembly so that the hole for the
pull rod is at the rear of the spout.
Installation
Remove the valve mounting nuts from the valves.
From below the mounting surface, push the valves up into
the holes. Install the mounting nuts on the valves.
Tighten the tensioning screws.
Place the handles over the valve mounting nuts. Tighten
the handles by rotating the escutcheons clockwise.
The handles should be parallel to the basin. If necessary,
loosen the tensioning screws and rotate the valve slightly.