ERROR CODES CONTINUED
ESC2
Short circuit at temperature sensor #2.
ESO2
Open circuit at temperature sensor #2
ESC3
Short circuit at temperature sensor #3
ESO3
Open circuit at temperature sensor #3
TROUBLESHOOTING
SYMPTOM
Heater does not turn on.
The blower does not turn
on during Cleaning Cycle,
Feeding Cycle, or Lighting
Cycle.
The blower does not turn on
during Stabilization Cycle.
During operation, including
the Lighting phase, the auger
is not filling the firepot with
pellets.
Grand Teton Wood Pellet Fire Stove
1. Check wires and connection points.
2. Contact Tech Support for assistance.
1. Check wires and connection points.
2. Contact Tech Support for assistance.
1. Check wires and connection points.
2. Contact Tech Support for assistance.
1. Check wires and connection points.
2. Contact Tech Support for assistance.
CAUSE
Power Switch
turned off.
Power Cord
1. Press power cord tightly into the heater
disconnected.
2. Ensure that the wall socket is delivering 120 Volts.
Fuse is blown.
This is normal.
No power in stove
or in control panel.
Mother board
disconnected.
Low Temperature
sensor is broken.
No fuel in Pellet
Hopper.
1. Unplug the unit so that it will not start suddenly
Auger is blocked,
2. Check that the auger is not blocked. If it is
jammed, or
disconnected.
3. Check that the auger screw fastening the auger to
23
SOLUTION
Turn on power switch.
Replace the fuse.
There is no problem, the blower does not turn on
until the stabilization cycle.
Check the power and wires.
Make sure all terminals to mother board are
connected.
Replace the low temperature sensor.
Add Fuel to Pellet Hopper.
and then unblock the auger.
blocked, remove the cause of the jamming.
the motor is secure.