4.2.2 Recomended minimum clearances for servicing
Should it be necessary to service the Tronic 5000C Pro,
observe the following clearances. These are not required
clearances, but would facilitate any service work.
Fig. 4
Recommended minimum clearances
Top (A)
Sides
Bottom (B)
Front (C)
Table 6
Recommended minimum clearances
Tronic 5000C
WH36
12"
0"
6"
12"
4.3
Mounting the water heater
WARNING:
▶ The heater must only be installed in the
orientation shown in Fig. 5 i.e., mounted
in a vertical position with the water
fittings located at the bottom of the
heater. Under no circumstances
should the heater be mounted
differently.
▶ Undo the retaining screws on the front cover and take the
cover off the heater. Hold the back plate in position against
the wall and mark the four mounting holes.
▶ Drill the holes and secure the heater using the four wood
screws supplied.
Fig. 5
Vertical mounting position
Installation | 9
6 720 647 022 (2014/06)