ASC5000RPA/ASC5500RPA
7.10.2
Refrigerant analysis failed
If the refrigerant fails the analysis, the AirConServiceCenter displays the
following:
1. Confirm "Try again" with ENTER.
The AirConServiceCenter checks up to three times. If the third analysis
is still not successful, the AirConServiceCenter displays the following:
2. Press STOP.
3. Connect the waste container to the waste terminal and press ENTER
to confirm.
4. Once the AirConServiceCenter has disposed of the sample, dis-
connect the AirConServiceCenter from the vehicle and drain the
service hoses.
5. Switch off the unit and take unit outside.
!
CAUTION!
Wear protective gloves and goggles.
6. Loosen the high and low pressure service connection carefully and
release the gas.
7. Verify the analysis unit of the AirConServiceCenter: see chapter
"Verifying the analysis unit" on page 88.
EN
Refrigerant Test
Fail
Try again?
ENTER-OK
WARNING !
Bad refrigerant!
Read user manual!
PLS contact the car
manufacturer!
ENTER-OK
Initial start-up
No
87