ASC5000RPA/ASC5500RPA
12. Unscrew the screw (D) from the holder, and pull the dryer filter
straight out.
13. Replace the O-rings (E). Moisten new O-rings with refrigerant oil
before installing.
14. Insert the new dryer and tighten the screw to max. 15 Nm.
15. Reconnect the power plug.
16. Switch on the unit.
✓ The inverter performs a self-test.
17. Fasten the cover again.
EN
E
Service tasks
D
111