ASC5000RPA/ASC5500RPA
✓ Afterwards the AirConServiceCenter runs a software test.
✓ Afterwards a leak test is performed.
Take unit outside.
Connect the power supply.
The unit shows the following message:
Press ENTER to confirm.
If the refrigerant vessel has an excessive proportion of non-conden-
sable gases (NCGs), the unit releases the non-condensable gases
automatically.
✓ Then the analysis unit is tested.
✓ When the start-up procedure is complete, the AirConServiceCenter
displays the following:
Press ENTER to confirm.
The unit shows the following message:
EN
Software test.
Please wait
Tightness test
Please wait
Switch off the unit
and place it outside
the workshop!
Unit in outer and
safe area?
No smoking!
Gas Analyzer test!
Connect the HP hose
to the external tank
of fresh R1234yf.
The unit is ready
for use.
Refrigerant
PAG oil
UV tracer
11:56:35
g.
XXXX
ml
XXX
ml
XXX
10/03/17
Initial start-up
79