2.3.
Basic connection (Local sensing)
(1)
Connect "+S" terminal to "+Vm" terminal with sensing wire
(2)
Connect "-S" terminal to "-Vm" terminal with sensing wire
(3)
Connect "CNT+" terminal to "CNT-" terminal with wire
Please use attached CN2 connector for each connection.
2-4. Remote sensing (+S. –S terminal)
(1)
Connect "+S" terminal to "+V" terminal of load with sensing wire
(2)
Connect "-S" terminal to "-V" terminal of load with sensing wire
(3)
Connect "CNT+" terminal to "CNT-" terminal with wire
If remote sensing terminal are opened, the stability and the accuracy of out deteriorated. Therefore, ter-
mal +S, -S must be connected.
Even when the supplied CN2 socket is not plugged in, the power supply will not go to OVP as there is
already an internal 10 ohm resistor connected to the output terminals.