7 Operation

7.1 Mounting the laser tool on the tripod adapter
7.1.1 Mounting point lasers, rotating lasers
or multidirectional lasers on the tripod
adapter 9 10
1.
Screw the PTA 70 tripod adapter onto the tripod
head.
2.
Place the Hilti laser tool under test on the adapter
plate and switch it on.
3.
Use the crank to adjust the height of the Hilti laser
tool so that the laser beam is aimed at the center of
the crosshairs in the middle of the filter disc.
7.1.2 Mounting the laser tool on the adapter plate
for the PP 10 and PP 11 pipe lasers
1.
Screw the PPA 73 tripod adapter onto the tripod
head.
2.
Place the pipe laser on the tripod adapter and switch
it on.
3.
Use the crank to adjust the height of the Hilti laser
tool so that the laser beam is aimed at the center of
the crosshairs in the middle of filter disc.
7.1.3 Switching on 11
Switch on the PT 10 quick check device.
7.2 Setting the accuracy class 11
1.
Select the applicable accuracy class 1-9 according
to the table of Hilti tools.
2.
Press the +/- buttons until the corresponding accur-
acy class appears.
7.3 Filter setting 11
1.
Select filter setting I or II according to the table of
Hilti tools.
2.
Move the switch on the filter disc to the correspond-
ing position.
7.4 Adjusting the camera 12 13
The position of the laser beam on the camera lens is
indicated by the yellow LEDs.
If neither of the yellow LEDs light up or only one LED
lights, turn the fine adjustment screw on the optical level
until the laser beam is found.
Both yellow LEDs light up as soon as the laser beam
strikes the camera. At the same time, the "Start meas-
uring" button becomes active and the device is ready to
begin the test.
7.5 Measuring 14
NOTE
Do not touch or move the PT 10 quick check device
while measuring is in progress. An error message will be
displayed in the event of vibration.
The PT 10 quick check device is ready to begin meas-
uring as soon as both yellow LEDs light and the "Start
measuring" button is shown to be active.
Press the "Start measuring" button. The measuring op-
eration is indicated by the yellow LEDs blinking and
continues, on average, for approx. 50 seconds.
7.6 Indication of result
NOTE
All 4 directional axes (X, Y) of rotating lasers must always
be tested.
After measuring for approx. 50 seconds, either the green
or the red LED lights to indicate whether the laser tool
under test is within the specified accuracy. If the green
LED lights, the laser tool is within the specified accuracy.
If the red LED lights, the laser tool is not within the
specified accuracy and should be returned to a Hilti
service center for calibration.
7.7 Repeating the test procedure
NOTE
The test procedure can be repeated with each Hilti laser
tool as often as desired.
7.8 Calibration
NOTE
Monitoring of measuring equipment for users certified in
accordance with ISO 9000X: The required procedure for
monitoring the PT 10 quick check device within the scope
of ISO 900X can be carried out by the owner. The PTA 20,
a tool specially designed for the purpose of calibrating the
PT 10 quick check device, is available from Hilti. Please
contact Hilti Customer Service for information about the
availability of this item.
7.8.1 Calibrating the PT10 quick check
device 15 16 17 18 19 20 21
NOTE
Calibration should be carried out at regular intervals. The
PTA 20 calibration tool, to be used for calibrating the
PT 10 quick check device, is available from Hilti . The
calibration tool should be sent to a Hilti service center in
advance for checking and calibration.
en