Télécharger Imprimer la page

SystemAir Fantech SHR 150 Manuel D'installation page 5

Masquer les pouces Voir aussi pour Fantech SHR 150:

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION EXAMPLES
Example only – duct configuration may differ depending on the model.
FULLY DEDICATED SYSTEM
BEST FOR NEW CONSTRUCTION
1.
Stale air is drawn from key areas of the home requiring local exhaust
(bathroom, kitchen, laundry room).
2.
Fresh air is distributed directly to habitable rooms in the house
(bedrooms, living room)
3.
The HRV's airflow must be balanced after installation using the procedure
found in the section "AIRFLOW BALANCING"
HRV ducting for fully Dedicated System
* Ductwork layout may dif-
fer depending on model
Fresh air from
outside
Stale air to
outside
* Unit air flow should be balanced while HRV is on "Normal" speed and
furnace blower is running.
Suggested installation for:
• Hydronic baseboard
• Infloor heating
• Electric baseboard
• Mini split heat pump
Benefits: Provides the best
fresh air distribution in the
house; lowest operation cost
since the furnace/air handler
unit is not needed.
Air from inside
Fresh air to
living areas
5

Publicité

loading

Ce manuel est également adapté pour:

Fantech shr 150r