Maintenance
29
45
32
20
E
19
A
A
19
101
B
C D
10
28
19 / 101
E
8.643-389.0 Manual - Trident Hillyard V12XP
CAUTION - Always unplug machine at mains
outlet before dismantling any part of machine.
If red light (d) shows, change paper filter bag. To do
this first pull cover release (5) picture 1 forward and
lift the cover from the dust bag housing. Slide the
dust bag sealing plate (28) from the holder (29). Slide
the sealing plate (28) of a new bag into the holder
and push firmly in. Insert cover into dust bag housing,
push it forward then lock it in place by pushing down
the cover release (5).
The micro hygiene filter (45) needs to be changed
when it becomes clogged with dust or after approxi-
mately 20 paper bags have been used. To change
the hygiene filter first remove the cover then slide the
filter out at the bottom. To replace lift the lever (32)
and slide the new filter in.
We recommend changing the exhaust filter (101) at
the same time as the micro-hygiene filter (45). The
exhaust filter is located underneath the cover (19) on
the back of the power head.
Removal of the exhaust filter
Disconnect machine from the mains
Move the dustbag housing into the upright position
and make sure that it is locked.
Remove the exhaust filter cover (19) by pressing the
two recessed grips (A) to the middle and lifting it
upwards.
The exhaust filter (101) is locked to the machine with
an additional catch (B). Lift the catch slightly and pull
the filter out of the housing.
Fitting a new exhaust filter
Slide the filters closed end first into the machine.
Fit filter end (C) to the air channel (D) and lock the
catch (B).
The correct positioning of the filter can be checked
through the slots (E) on the front of the power head.
Please ensure it is smooth and flat
Finally replace the exhaust filter cover (19). Fit it to
the top of the opening in the power head housing and
move it downwards until an audible click occurs.
The filters must not be washed.