O p e r a t i n g a n d I n s t a l l a t i o n P r o c e d u r e s
Kleen-Change
®
100 and CMP Kleen-Change
Disposable Filter Assemblies
1.
SPECIFICATIONS
Materials of
Construction:
Polypropylene
Inlet/Outlet
Connections:
1" Tri-Clover*, or
1" Camlever type
(to DIN2828 or A-A-59326 –
previously known as
MIL-C-27487),
compatible connections
For use with fully compatible liquids (those liquids
which do not soften, swell or attack
the filter assembly, or adversely effect the materials of
construction of the product), please refer to Table 2.
For other liquids, please contact Pall.
The maximum allowable time of continuous use is
7 days.
If use is not continuous, maximum cumulative
allowable use time before disposal from start of the
first use is 7 days.
Maximum Allowable
Differential Pressure:
Maximum Allowable
Temperature:
Minimum Allowable
Temperature:
Weight full of Water:
TABLE 1
Kleen-Change
Empty Weight
100 Assembly
of Assembly
(kg)
1 head x 1 high
0.6
1 head x 2 high
1.0
1 head x 3 high
1.3
1 head x 4 high
1.7
2 head x 2 high
1.8
2 head x 3 high
2.6
2 head x 4 high
3.2
3 head x 3 high
3.8
3 head x 4 high
4.8
4 head x 4 high
6.3
4 bar / 58.02 psi
30 °C / 86 °F
5 °C / 41 °F
Refer to Table 1
Weight when Assembly
full of water
(lbs)
(kg)
(lbs)
1.32
1.7
3.75
2.2
3.0
6.61
2.86
4.3
9.48
3.75
5.5
12.13
3.97
5.8
12.79
5.73
8.3
18.30
7.05
10.6
23.37
8.37
12.3
27.12
10.58
15.9
35.05
13.89
21.1
46.52
®
100
WARNING!
THE USE OF THESE FILTER ASSEMBLIES
SHOULD NOT EXCEED ONE WEEK OF
OPERATION
Operation outside of the above limits and
with fluids incompatible with the materials
of construction may cause fracture resulting
in personal injury and/or damage to the
equipment.
The following procedures are required to assemble
and install the Kleen Change 100 series and CMP
Kleen-Change 100 series filter assemblies. They
should be thoroughly read as they contain valuable
information gained by extensive experience. It is
very important that all instructions are carefully
followed. If some of the procedures do not suit your
needs, please consult Pall or your local distributor
before finalising your system.
Pall have evaluated the solvents listed in Table 2 in
order to demonstrate that the Kleen-Change 100
series and CMP Kleen-Change 100 series
assemblies (excluding protective caps) are a
suitable method of filtration within the limits of time,
temperature and pressure given in the above
specifications. However, users should satisfy
themselves that either the Kleen-Change 100 series
or CMP Kleen-Change 100 series filter assemblies
meet their requirements in terms of process
specifications and local Health and Safety and
Environmental requirements or Procedures.
Contained
Liquid Volume
(l)
(USG)
1.1
0.29
2.0
0.53
3.0
0.79
3.8
1.00
4.0
1.06
5.7
1.51
7.4
1.95
8.5
2.25
11.1
2.93
14.8
3.91
3