Télécharger Imprimer la page

Abus TVIP31000 Manuel Utilisateur page 85

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.4 Alarm input and output
Adhere to the following connections and maximum loads for the digital
alarm input and output.
Connection
Description
DO – Alarm
Connection of a transistor or relay:
output
Transistor: NPN with emitter against
Relay:
DI – Alarm input
Activation of the digital input by con-
necting the DI and GND connections
GND
Ground connection
12 VDC
Voltage output
Connection example:
Please carefully observe the connection instructions and power specifications!
4.5 Setting the focus
TVIP31000, TVIP31050, TVIP31500 and TVIP31550 cameras are equipped with a fixed lens. The zoom is
fixed on these cameras. However, the focus can be adjusted here by turning the lens by hand when required.
ground (GND)
12 VDC "and" connection,
plus DO with diode
(see example below)
85
Max. load (V/A)
24 VDC, 100 mA
-
-
12 VDC, max. 100 mA

Publicité

loading

Ce manuel est également adapté pour:

Tvip31550