Télécharger Imprimer la page

noken BELA 100200091_N168199963 Manuel D'installation page 13

Publicité

ADJUSTING THE SETTINGS WITH THE REMOTE CONTROL (To be orderet separately)
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control, hold the remote control straight
in front of the sensor in a distance of about 6-8" (15-20cm). Choose the function you want to adjust by pressing
Once on one of the function buttons. After pressing once on a specific function button, a quick flashing of the red light
at the front of the sensor will occur. at this stage, you can change the setting by pressing the (+) or the (-) buttons,
every push will increase or decrease one level. After finishing the adjustment, turn the water supply back on.
DETECTION RANGE: Only if necessary, use the remote control to adjust the sensor range as follows:
Press the RANGE button. Wait until a quick flashing of the red light of the sensor eye is perceived.
Then, press + to increase the one level and - to reduce it every push will increase or decrease one level.
NOTE: Once you have changed the detection range with the remote control,
this distance will be remembered by the sensor, even if the power source is disconnected.
SECURITY TIME: The Security time, prevents continuous running of water due to reflections
or vandalism. By dafault, if the sensoris covered for more than 10 minutes the water flow will
shut automatically. To resume regular operation any obstruction must be removed.
Press the SEC button. Wait until a quick flashing of the red light of the sensor eye is perceived.
Then, press + to increase the security time and - to reduce it.
DELAY IN TIME: It is recommended to change the delay in time for flush valves for urinals or toilets
valves for urinals or toilets only.
If required, the delay in time can also be modified in faucets as follows: Press the IN button. Wait
until a quick flashing of the red light of the sensor eye is perceived. then, press + to increase the
delay in time and - to reduce it.
DELAY OUT TIME: This button allows modifying the water flow time after the user removes his hands
from the faucet. A delay out time close to 0 will save more water. An increased delay out time will make
the user experience more confortable.
If required, the delay out time can be modified as follows:
24 HOUR HYGIENE FLUSH: If you have a compatible model with a 24 hours hygiene flush it is possible
to enable and disable it.
To activate the hygiene flush, press the clock button. wait until a quick flushing of the red light of sensor
eye is perceived. Then press + to activate the hygiene flush or - to deactivate it.
TEMPORARY OFF FUNCTION: This function is ideal to perform any kind of activity in front of the sensor
without operating the system (for example, cleaning). The faucet will remain shut for 1 minute when
this button is pressed once.
To cancel this function and to return to normal operation press the On/Off button again or wait 1 minute.
RESET BUTTON: This function restores all the factory settings except for the sensor range. If required, press
the Reset button and without releasing it, press the + button once.
DETECTION
DELAY OUT TIME
RANGE
TEMPORARY OFF
DELAY IN TIME
SECURITY TIME
HYGIENE FLUSH
FUNCTION
RESET
13

Publicité

loading

Ce manuel est également adapté pour:

Bela 100200093_n168199964