L'Étiquette de sÉcuritÉ
Voici une copie de l'étiquette apposée sur chaque foyer à gaz encastrable
HZI390E afin de vous permettre d'en examiner le contenu. Cette étiquette
de sécurité se trouve à l'intérieur de la base de l'appareil, à l'avant, et est
visible lorsque la grille d'aération inférieure est ouverte.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel
Gas Code ou CSA-B149.1 en vigueur.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements.
AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut être utiliser pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remplacées et que le foyer ait été approuvé de nouveau par l'autorité compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
For use only with barrier (Part # 397-929) Follow installation instructions.
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz, Less than 10A
VENTED GAS FIREPLACE HEATER -
GAZ À ÉVACUATION -
Pour les régulations pour l'État de Massachusetts référez à notre notice en anglais pour les détails complets
6
Listed:
VENTED GAS FIREPLACE HEATER
/
FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour: CANADA and U.S.A.
é
Tested to:
CAN/CGA-2.17-M91(R2009)
Conforms to:
ANSI Z21.88a-2012
4001172
Certified to:
CSA 2.33a-2012
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Maximum input
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Maximum input
Minimum Clearances to Combustibles
from Insert
Side wall
A
6"
(152mm)
Ceiling
B
60"
(1524mm)
Mantel
C
24"
(610mm)
Min. Alcove Width
K
54"
(1372mm)
Max. Alcove Depth
L
36"
(914mm)
Regency Fireplace Products,
Delta BC, CANADA
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
REMARQUE: Nous améliorons constamment nos produits Regency
Comparez cette copie avec l'étiquette apposée sur votre appareil. S'il
existe une différence, fiez-vous à cette dernière.
Duplicate Serial number
NE PAS ENLEVER CETTE ETIQUETTE
Serial No. / No de serie
MODEL HZI390E-NG2
É
QUIP A L'UISINE POUR GAZ NATURAL
É
MODEL HZI390E- NG2
5"
WC
(1.25 kpa)
Pression d'allimentation minimum
1.6"
WC
(0.41 kpa)
Pression la tubulure d' chappement basse
3.5"
WC
(0.87 kpa)
Pression la tubulure d' chappement lev e
#35
DMS
Dimensions de l'orifice
22,000
Btu/h
(6.45
kW
)
D bit Calorifique minimum
é
31,000
Btu/h
(9.09 kW)
D bit Calorifique maximum
é
MODEL HZI390E-LP2
É
QUIP A L'UISINE POUR GAZ PROPANE
É
MODEL HZI390E- LP2
11"
WC
(2.73 kpa)
Pression d'allimentation minimum
6.4"
WC
(1.59 kpa)
Pression la tubulure d' chappement basse
10"
WC
(2.48 kpa)
Pression la tubulure d' chappement lev e
#53
DMS
Dimensions de l'orifice
26,000
Btu/h (7.62 kW)
D bit Calorifique minimum
é
31,000
Btu/h (9.09 kW)
D bit Calorifique maximum
é
Mantel Clearances
Min. Hearth Width
Min. Hearth Length
A
A
Max. Mantle Depth
G
G
.
C
C
L
L
B
B
D
D
E
E
MADE IN CANADA /FABRIQUE AU CANADA
K
K
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
Pour l'utilisation seulement avec la Partie de barrière No. (397-929)
Suivez les instructions d'installation.
Fan Part # 911-071
NOT FOR USE WITH SOLID FUELS. /
L390E-2 / HZI390E-2 Foyer à gaz encastrable
398
DO NOT REMOVE THIS LABEL /
398
é
à
é
é
é
à
é
à
é
é
é
à
D
14"
(356mm)
E
40"
(1016mm)
G
12"
(305mm)
FOYER AU
919-235a
.
MD