LE10 Radio Receiver
2.3
Main applications
LE10 Radio Receiver as small stand alone call system
After receiving a radio signal from a programmed radio
transmitter, the relay output switches a siren or a lamp to
indicate locally a wireless call.
LE10 Radio Receiver connected to a nurse call system via
relay contact
After receiving a radio signal from a programmed radio
transmitter, the relay will be switched. This relay output is
connected to a wired nurse call system by wire and hereby a
call will be generated or forwarded.
LE10 Radio Receiver as part of a NurseCall dementia system
After receiving a signal from a dementia transmitter, the relay
will be activated to close a monitored door.
2.4
Description of the different modes
Mode Name
1
Normal
2
Normal, with LED 2
deactivated at
battery-low
indication
3
Dementia
Bosch Security Systems
Description
20 wireless transmitters can be
programmed. Calls are indicated by LED 2
and Relay 1. A battery-low signal is indicated
by LED 2 and Relay 2.
The same functions as in mode 1 are
available, except for the battery-low signal
which is not indicated by LED 2, but only by
Relay 2.
The S37L and S37E wireless transmitters are
detected. Relay 1 can be used to lock a
monitored door. Relay 2 can be used to
interrupt a monitoring loop.
User Manual
Product information | en
F.01U.139.675 | V1 | 2009.10
31