Télécharger Imprimer la page

Gessi 57823 Mode D'emploi page 27

Programme du mitigeur pour la salle de bain
Masquer les pouces Voir aussi pour 57823:

Publicité

ELECTRICAL SYSTEM - SYSTÈME ÉLECTRIQUE -
A - SHOWER HEAD CONTROL UNIT
Installinthesafetyzone:Z1
Power:24W
Input:12Vdc,2A(max)
 O utput:
1.
LED:RGB+WIP6712Vdc(Art.57821-57823-57825-57827-57829-57831power11W(max);Art.57921-57927power15W(max);
Art.57923-57929power20W(max))
2.
KEYBOARD:connectorIP67-PG7
3.
PRESENCESENSOR"PIR":connectorIP67-PG7
4.
SerialPort(RS485):connectorIP67-PG7
Servicetemperature:0°F[0°C]÷122°F[50°C]
Protection:IP66
B - REMOTE CONTROL
Installinthesafetyzone:Z1-Z2-Z3
Protection:IP66
Battery:CR2032
C - POWER SUPPLY (can be ordered as come optional)
Installinthesafetyzone:Z3
Input:100-240Vac,0.59÷0.29A,50÷60Hz
Output:12Vdc,2A(max)
Standard:CSAC22.2N.223/UL13.10
D - CAPACITIVE KEYBOARD CONTROL (can be ordered as come optional)
Installinthesafetyzone:Z1-Z2-Z3
E - TRADITIONAL CONTROL (no order possible)
Installinthesafetyzone:Z3
ToinstalltheledcontrolinthesafetyzoneZ3,thecapacitivekeyboardcontrolcanbeexcludedinfavorofatraditionalcontrol,equippedwithat
least two buttons, with the finish plate meeting the specific requirements of the customer. A solution conceived to offer the largest choice of shapes,
finishes and materials.
WARNING:thetwosolutionsproposedfortheinstallationoftheledcontrolcanbeassociated,givingthepossibilityoftwocontrols,oneinsidethe
shower tray and the other in the bathroom.
F - POWER SUPPLY/CONTROL UNIT PER SENSOR PIR (can be ordered as optional)
Installinthesafetyzone:Z3
Power:<1W
Input:110Vac
Safety:IP20/II/ULSTD60730-1/CSASTDE60730-1
Servicetemperature:9°F[-25°C]÷122°F[50°C]
G - PRESENCE SENSOR "PIR" (can be ordered as come optional)
Installinthesafetyzone:Z1-Z2-Z3
Safety:IP65/II/ULSTD60730-1/CSASTDE60730-1
Servicetemperature:0°F[0°C]÷122°F[50°C]
Serial Port (RS485) - Connection for communication kit (to order as an option) between two or more synchronized control units, in the
MASTER-SLAVE configuration
Connection between A-C
Lengthmax=26ft[8m]
Poles=2
Section=20-22AWG
Connection between A-D
Lengthmax=23ft[7m]
Cablediameter:3/16"÷1/4"[4÷6mm]
Poles=6
Section=24AWG
Connection between A-E
Lengthmax=23ft[7m]
Cablediameter:3/16"÷1/4"[4÷6mm]
Poles=3(GNDcommon)
Section=24AWG
Connection between A-F
Lengthmax=33ft[10m]
Cablediameter:3/16"÷1/4"[4÷6mm]
Poles=2
Section=20AWG
Connection between A-Serial Port (RS485)
Lengthmax=33ft[10m]
Cablediameter:3/16"÷1/4"[4÷6mm]
Poles=2
Section=20AWG
WARNING:
- the connection to a cut out switch with intervention current not greater than 30mA is mandatory.
- on the supply cable "L+N" (not included), to guarantee compliance with the requirements of Electromagnetic Compatibility, it is necessary
to position the following ferrite: Trademark: Fair-Rite Products Corp - Model: 431164281 or a component with similar characteristics.
INSTALACIÓN ELÉCTRICA
DATA FOR THE ELECTRICAL SYSTEM
ELECTRICAL CONNECTIONS DATA
27

Publicité

loading

Ce manuel est également adapté pour:

578215782557827578295783157921 ... Afficher tout