Switch off the unit and remove the
two air filters.
CLEANING UP OF REFRIGERANT
General Measures:
1.
Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or
below ground level.
2.
Eliminate every possible source of ignition.
3.
Use appropriate personal protection equipment (PPE).
4.
Evacuate unnecessary personnel, isolate, and ventilate area.
5.
Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
6.
Prevent entry to sewers and public waters.
7.
Stop the source of the release, if safe to do so. Consider the use of water spray to
disperse vapors.
8.
Isolate the area until gas has dispersed. Ventilate and gas test area before entering.
Contact competent authorities after a spill.
2021-11-18 OCG BluMill Portable Air Conditioner V08056 Manual V03.indd 15
2021-11-18 OCG BluMill Portable Air Conditioner V08056 Manual V03.indd 15
Rinse the air filter under running
water.
EN
15
29-11-2021 15:25
29-11-2021 15:25