TIMER SETTING (1hour-24hours):
The timer has two ways of operation:
To turn off
(When power on)
To turn on
(When power off)
Cancel timer
Automatic Defrost
At low room temperatures, frost may buildup at the evaporator during operation. The
unit will automatically start defrosting and the POWER LED blinking. The defrost control
sequence is as follows:
A.
When the unit operates in the cooling operation, drying operation, the ambient
temperature sensor senses the evaporator coil temperature is below -1°C, after the
compressor will stop operating for 10 minutes or the coil temperature up to 7 , the
unit restart to cool operating mode.
B.
When the unit operates in the drying operation, once the coil temperature sensor
senses the temperature of the evaporator is below 40 and the differential tempera-
ture between coil temperature and room temperature is below 19 after the compres-
sor operation for 20minutes, the unit start defrosting for 5 minutes and the power
indicator blinking.
Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the
compressor restarting.