7. Maintenance
To inspect or replace either the valves or the diaphragm,
disconnect electrical supply the user must firstly remove
the pump head clamping rings, this is done by unscrew-
ing the 2 clamping screws.
This will release the pump head, and allow easy access
to the valves & diaphragm. The diaphragm and valves
should be checked for any excessive wear, damage or
cracks, and should be replaced if necessary. If the
diaphragm needs to be replaced, undo the nut in the
centre of the diaphragm and remove the diaphragm plate
& diaphragm. Note: The centre pin may be in one of
several positions, this will not affect replacement of the
diaphragm). When replacing the diaphragm this can
be fitted either cup up or down. Replace clamping plate
making sure the rounded edge faces the diaphragm, also
ensure that the outer sealing edge of the diaphragm is
located securely in the grooves between the body & gear
housing (failure to do this will cause the pump NOT to
prime). Refit clamping rings and
tighten screws.
8. Fault Finding
The electric motor runs but no water is pumped?
Check:
a) that inlet hose connection is airtight, free from
blockages, and does not collapse.
b) that the shower/sink drain is not clogged.
c) that the valves in the pump are not blocked & are
seating properly in the pump head.
d) that the diaphragm has not split - replace if damaged.
The motor will not operate?
Check:
a) the isolator switch is on.
b) there is 12 volts from the battery.
c) the in-line fuse & ensure all electrical connections are
tight and free from corrosion. (If fuse has blown check for
debris in pump head and clean out if necessary replace
fuse and run pump - see previous page).
9. Service Kits
Spares Kit Part No: AK1550.
Any questions contact our service desk -
Email: support@whalepumps.com.
10. Warranty
Whale Gulper pumps are guaranteed for 2 years from
date of purchase. This covers defects in materials and
workmanship. If the unit proves faulty return it to your
Munster Simms Engineering Ltd
2 Enterprise Road, Bangor, Co Down, Northern Ireland, BT19 7TA
Tel: +44 (0)28 9127 0531
Email: info@whalepumps.com Web: www.whalepumps.com
supplier with proof of purchase date.
The manufacturer retains the right to decide whether to
repair or replace the unit. The manufacturer cannot be
held responsible for claims arising from incorrect
installation, unauthorised modification or misuse of the
product.
The above does not affect your statutory rights.
11. Declaration of Conformity
Declaration no.: EU-MSE002-002
We the undersigned:
Name of manufacturer: Munster Simms Engineering Ltd
Address:
Country:
We herewith declare, under our sole responsibility, that
the enclosed equipment complies with the provisions of
the following EC Directives.
Standards applied
2013/53/EU
2014/30/EU
EN55014-1:2006
EN55014-2:1997+
A2:2008
EN28846:1993
ISO8849:2003
ISO15083:2003
ISO10133:2012
Name:
Richard Bovill
Function:
Engineering Director
Location:
Munster Simms Engineering Ltd
Date of Issue: 28 April 2016
2 Enterprise Road
Bangor BT19 7TA
Northern Ireland
Recreational Craft Directive
EMC Directive
EMC Emissions
EMC Immunity
Ignition Protection
Electrically Operated Bilge
Pumps
Bilge Pumping Systems
Extra-low Voltage d.c.
Installations