Part Description
PSE Pilot Orifice
Main Burner Orifice
SIT Gas Valve Conversion Kit
Gas Conversion Label
Tools Needed: Standard Screwdriver, 1/4" Hex Driver, 5/16" Hex Driver, 3/8" and 1/2" Wrenches
Gas input for direct vent fireplace insert converted to
Propane gas:
DVC20IN71 - 19,500 BTU per hour
DVC26IN71 - 26,000 BTU per hour
DVC28IN71 - 27,500 BTU per hour
The direct vent gas fireplace insert when converted to Propane
gas will have a manifold pressure approximately 10.0" w.c.
(2.49 kPa) at the valve outlet with the inlet pressure to the valve
from a minimum of 10.8" w.c. (2.68 kPa) for the purpose of input
adjustment to a maximum of 14.0" w.c. (3.48 kPa).
INSTRUCTIONS FOR CONVERSION
1. If the fireplace insert is installed, turn OFF gas and electric
supply to fireplace before making gas conversion.
2. Remove barrier screen. Refer to instructions provided with
the fireplace for removal information.
3. Release two glass frame spring clamps at bottom of firebox.
4. Remove glass frame assembly.
5. Remove logs from burner assembly.
6. Remove two 10 x 1/2" screws from rear log support. Remove
log support.
7. Remove four (4) 10 x 1/2" screws from burner/grate base
and one 8 x 1/4" screw from air shutter. Grasp burner/
grate base assembly, lift and pull forward to remove burner
assembly. Use a screwdriver to gently separate the air
shutter from the burner venturi tube at rear of burner.
8. Remove air shutter from orifice fitting. Use a 3/8" and 1/2"
wrench to remove burner orifice.
9. Remove Natural gas main burner orifice from orifice fitting.
10. Install Propane gas main burner orifice into orifice fitting:
for DVC20IN71 USE ORIFICE MARKED 1.30 mm
for DVC26IN71 USE ORIFICE MARKED 53
for DVC28IN71 USE ORIFICE MARKED 1.55 mm
The main burner flame and pilot burner flame must be
checked for proper flame characteristics, as outlined in the
Installation Instructions and Owner's Manual.
Verifying Input Rate of Converted Fireplace
The input of the fireplace must be checked as follows:
1. Turn off all other gas appliances. Clock the gas meter
and determine the number of seconds required to
consume one cubic foot of gas.
2. 3600 ÷ time (in seconds) = cu. Ft. per hour.
3. Then cu. Ft. per hour x heating value of gas = input
rate (Btuh). On installation without gas meters, check
manifold for proper pressure.
Page 2
Conversion Kit - 36723 Conversion Kit - 36725 Conversion Kit - 36727
R10426
P266 (1.30 mm)
R11169
36723-2139
Empire Comfort Systems Inc. • Belleville, IL
PARTS LIST
R10426
P214 (#53)
R11169
36725-2139
11. Thread air shutter onto orifice fitting.
12. Pull upward on pilot hood to remove and gain access to pilot
injector orifice.
13. Remove Natural gas pilot injector orifice from pilot burner
with 5/32" hex (Allen) wrench.
14. Insert Appropriate Propane gas pilot injector orifice into
pilot burner using the 5/32" hex wrench.
15. Re-install pilot hood to pilot assembly. Push downward to
snap in place.
16. Convert the gas valve as instructed in S.I.T. Propane Gas
Valve Conversion Kit.
17. Align burner assembly/grate base with the air shutter as you
place burner assembly into the original position in firebox.
18. Adjust air shutter setting to 1/2" Open on all models.
19. Attach air shutter to burner assembly with one 8 x 1/4" screw
from Step 7.
20. Attach burner assembly/grate base to firebox bottom with
four 10 x 1/2" screws from Step 7.
21. Attach rear log support with 10 x 1/2" screws from Step 6.
22. The converted fireplace must be connected to a supply of
the conversion gas and checked for leaks at all connections.
23. Refer to Log and Ember Placement in your Installation
Instructions and Owner's Manual to place logs onto burner
assembly.
24. The fireplace must be checked to ensure it is operating at
the correct pressure of 10.0" w.c.
25. Replace glass frame onto firebox.
26. Secure the two glass frame spring clamps at bottom of
firebox to secure glass door assembly.
27. Replace the barrier screen assembly. Refer to instructions
provided with the replacement for removal information.
28. Gas conversion is completed.
If fireplace insert is not installed or warranty card has not
been returned to Empire Comfort Systems, Inc., check off
type of gas converted to on card. Also, indicate conversion
by adding "Conv." behind type of gas.
Quantity Supplied
R10426
P258 (1.55 mm)
R11169
36727-2139
1
1
1
1
41337-0-1119