Standard device 0
Pos.
MXI1
MXI2
MMI
MSI
X1
X2
X3
X4
X5
X6
X7
X8
2
3
4
8
X100
X105
X106
X107
6 7
9
:
The LED display enables fast indication of several operating states.
LED
Labelling
CAN−RUN
CAN−ERR
DRIVE READY
DRIVE ERROR
24 V
USER
SSP94LED01
Pos.
Symbol
{
}
5
'
EDK94MH594 DE/EN/FR/ES/IT 3.0
Description
Module receptacle for extension 1, e.g. communication
Module receptacle for extension 2, e.g. communication
Module receptacle for memory modules
Module receptacle for safety equipment
System bus (CAN), under the cover
24 V supply and statebus
Analog inputs and analog outputs
Digital outputs
Digital inputs
Diagnostics
Resolver
Encoder
Lower cover
Retractable nameplate
Upper cover
EMC clip
DC−bus voltage
Motor
Motor temperature monitoring
Control of motor holding brake
EMC wire clamp
Æ 10 ... 20 mm and Æ 15 ... 28 mm
Device size 6:
Internal thread for M6 eye bolt (not included in the scope of supply)
Strain relief and lifting aid, removable
Colour
green
red
green
red
green
yellow
Description
Long discharge time: All power terminals carry hazardous electrical voltages
for a longer period of time after mains disconnection! Depending on the
device, this period of time may be up to 30 minutes.
High discharge current: Carry out fixed installation and PE connection accor-
ding to EN 61800−5−1!
Electrostatic sensitive devices: Before working on the device, the personnel
must be free of electrostatic charge!
l
Description
CAN bus ok
CAN bus error
Standard device is ready for operation
Error in the standard device or application−induced
24 V supply voltage ok
Message parameterised by the application