Télécharger Imprimer la page

HEATFAST HF15TT Mode D'emploi page 8

Publicité

• Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious
leak. Immediately go into action as discussed previously.
ATTENTION - CRITICAL POINTS TO REMEMBER
• Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections
to the left and above).
• Even if you are not property trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of
propane (LP) gas and natural gas.
• If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform
service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.
• A periodic sniff test around the heater or at the heater's joints; i.e. hose, connections, etc., is a good safety practice under any
conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!
GENERAL INFORMATION
A. These units are high pressure propane appliances and are designed to be connected to a bulk propane tank.
B. These heaters are equipped with an automatic Safety Shutoff Valve. The gas flow will automatically stop if the heater fails to
operate for any reason.
C. Maximum safety and convenience have been built into the Hi-Med-Lo-Off Control Valve/Regulator. The following table lists
the approximate BTU's consumed and the operating hours you can reasonably expect from bulk propane cylinders.
D. These heaters are for temporary heating of buildings under construction, alterations, or repair.
Model
Valve Position
Hi
Med
Lo
FOR SAFE OPERATION
A. READ INSTRUCTIONS CAREFULLY: Read and adhere to these instructions. Do not allow anyone who has not read the
instructions to assemble, light, adjust or operate the heater.
WARNING: KEEP THE HEATER OUT OF THE REACH OF CHILDREN
B. Use only in accordance with local codes or, in the absence of local codes, with the standard for the Storage and handling of
Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B 149.1, Natural Gas and Propane Installation Code.
C. PROPANE IS VERY FLAMMABLE: In the event of a leak, propane will accumulate and the possibility of a fire is present.
Propane gas is scented and its strong odor is readily detectable. Never strike a match or bring any flame or create an electric
spark in an enclosure when you smell propane gas. Ventilate the area thoroughly, move the heater outside, find and correct
the source of the leak before attempting to light any appliance. If you are unsure of these instructions evacuate immediately
and call for help.
D. GAS LEAKAGE: If the leak cannot be corrected do not tamper with the heater, follow the shut down instructions and return
the heater to the dealer or address given on last page.
WARNING: DO NOT USE THIS HEATER ON BULK TANKS OF GREATER CAPACITY THAN 20 POUNDS LPG (50 POUNDS
WATER CAPACITY).
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
IMPORTANT INFORMATION
HF15TT
BTU Input
Hours w/20lb. Tank
15,000
12,000
10,000
BTU Input
28
30,000
36
24,000
43
10,000
-8-
HF30TT
Hours w/ 20lb. Tank
14
18
43