Testing your Dimmer prior to mounting in
Step 5
wall box:
NOTE: If using in a dimmable luorescent application see
Advanced Programming Feature A-1 prior to testing the device.
• Position all wires to provide room
in outlet wall box for device.
• Ensure that the word "TOP" is
facing up on device strap.
• Partially screw in mounting screws
in wall box mounting holes.
NOTE: Dress wires with a bend as
shown in diagram in order to relieve
stress when mounting device.
• Restore power at circuit breaker or fuse.
• Press pad until locator light is OFF. Lights
should turn ON. If lights do not turn ON,
press the TOP half of the DIM/BRIGHT
Bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Dimmer Mounting:
Step 6
TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Restore Power:
Step 7
Restore power at circuit breaker or fuse.
Installation is complete.
NOTE: To pair your dimmer with your mobile device, download the
Leviton Decora
®
Digital Dimmer and Timer app from the Google Play
Store or your iTunes account. Contact Leviton's Techline at 1-800-
824-3005 or visit Leviton's website at www.leviton.com for additional
information.
OPERATION
LED Brightness
Display
NOTE: The locator light will illuminate when
DIM/BRIGHT
the load is in the OFF position to facilitate
Bar
access in the dark.
NOTE: If using the dimmer in a 3-way
application, the lights will turn ON at
brightness set on dimmer's DIM/BRIGHT bar.
The lighting can be controlled from either the
dimmer, the remote location or the mobile
device app.
Push Pad (Default settings)
Turn ON from OFF position:
Tap TOP of Rocker: Lights turn ON to preset
level.
Turn OFF from ON position:
Tap BOTTOM of Rocker. Lights turn OFF.
Rocker
Locator
Light
DIM/BRIGHT Bar
BRIGHTEN:
Press the TOP half of the DIM/BRIGHT Bar – Lights brighten to desired
level.
DIM:
Press the BOTTOM half of the DIM/BRIGHT Bar – Lights dim to desired
level. If you continue to hold, the lights will DIM to minimum level and
then turn OFF.
NOTE: When lights are OFF you can change the light level that the
lights will turn ON to using the DIM/BRIGHT Bar. If there is a power
outage, when the power is restored, the lights will return to the last
setting before the power interruption.
Leviton warrants to the original consumer purchaser and not for the beneit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ive years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option. For details
visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating
conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and itness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and itness for a particular purpose,
is limited to ive years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or proits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Air-Gap Switch: On the dimmer only, engage
the air-gap switch by gently pulling out from the
bottom of the DIM/BRIGHT bar until the bottom
of the bar lifts completely out of the frame and a
click is heard (refer to Figure). LED's will turn
OFF. This will stop power to the ixture to replace
the bulb. After servicing is complete, press the
DIM/BRIGHT Bar back into place for normal
operation.
Cleaning: Clean with a damp cloth.
DO NOT use chemical cleaners.
Gently pull out
from bottom
ADVANCED PROGRAMMING FEATURES
Deinition of A Modes
A-1) Load Type Selection
A-2) Maximum Brightness Level: Sets the maximum brightness level for
energy savings.
A-3) Minimum Brightness Level: Sets the minimum dimming level.
A-4) Preset ON Level: Sets the turn on brightness level regardless of
the previous set light level.
Deinition of B Modes
B-1) ON Fade Rate: Sets the amount of time in seconds it takes the
lights to turn ON to maximum brightness.
B-2) OFF Fade Rate: Sets the amount of time in seconds it takes the
lights to turn OFF from maximum brightness.
B-3) LED Options: Sets the time period in seconds the Locator LED
and Brightness display will stay on before extinguishing.
Deinition of LEDs
Bottom LED = LED 1
Top LED = LED 7
LED 7
Dim/
NOTES:
Bright
Bar
• The device will exit programming
mode after 3 minutes of inactivity.
• Pressing the TOP of the Rocker at
any time during programming will
LED 1
advance the device to the next
programming mode.
Program Mode A
Locator LED
To enter Program Mode A:
Press and hold the TOP of the Rocker and the TOP of the DIM/BRIGHT
Bar simultaneously for 5 seconds until the Locator LED begins to blink.
A-1) Upon releasing the TOP of the Rocker and the TOP of the DIM/
BRIGHT Bar, the Locator LED will continue to blink once per
second to display the device is in Program Mode A-1, Load Type
Selection. The bottom LED will illuminate to display that the Load
Type selected is Electronic Low Voltage load (default load type).
To change the load type, use the DIM/BRIGHT Bar to change the
corresponding LED to the desired load type according to the
Load Type Chart below. By tapping the TOP of the Rocker, this
setting will automatically be saved and the device will advance to
the next Programming Mode, A-2, Energy Save
(Maximum Brightness Level).
LOAD TYPE CHART
When indicator is at LED #
Selected Load Type is
1
Electronic Low Voltage
2
Incandescent
3
LED
4
CFL
A-2) Maximum Brightness Level: NOTE - Energy Save Mode can only
be used with an incandescent or electronic low voltage load. The
Locator LED will blink 2 times per second to indicate the device is
in Program Mode A-2, Maximum Brightness Level. The default
Maximum Brightness Level is LED 7, representing 100% light output
i.e. full brightness. To change the Maximum Brightness level form
100% to the desired output level, use the DIM/BRIGHT bar. The
Maximum Brightness level can be changed from LED 7, representing
maximum light output, to LED 4, representing minimum light output.
By tapping the TOP of the Rocker this setting will automatically be
saved and the device will advance to the next Programming Mode,
A-3, Minimum Brightness Level.
A-3) The Locator LED will blink 3 times per second to indicate the device is in
Program Mode A-3, Minimum Brightness Level. The default Minimum
Brightness Level is LED 2. To change the Minimum Brightness Level
from 1-50%, use the DIM/BRIGHT Bar. The light output will relect the
minimum brightness level selected. By tapping the TOP of the Rocker
this setting will automatically be saved and the device will advance to the
next programming mode, A-4, Preset ON Level.
A-4) The Locator LED will blink 4 times per second to indicate Program
Mode A-4, Preset ON Level. To change the current Preset ON
Level from 1-100%, use the DIM/BRIGHT Bar. If this feature is not
desired, press and hold the BOTTOM half of the DIM/BRIGHT Bar
until LED 1 is lit, and then keep holding for another two seconds.
By tapping the TOP of the Rocker this setting will automatically be
saved and the device will exit Programming Mode A.
Program Mode B
To enter Program Mode B:
Press and hold the TOP of the Rocker and then the BOTTOM of the DIM/
BRIGHT Bar for 5 seconds until the Locator LED and the TOP LED (LED 7)
begin to blink.
B-1) Upon releasing the TOP of the Rocker and the BOTTOM of the DIM/
BRIGHT Bar, the Locator LED will continue to blink once per second
indicating the dimmer is in Program Mode B-1, ON Fade Rate. To
change the ON Fade Rate, use the DIM/BRIGHT Bar to move the
LED to the desired preset level according to the Fade Rate Chart. By
tapping the Top of the Rocker this setting will automatically be saved
and the device will advance to the next programming mode, B-2, OFF
Fade Rate.
B-2) The Locator LED will blink 2 times per second to indicate Program
Mode B-2, OFF Fade Rate. To change the OFF Fade Rate, use
the DIM/BRIGHT Bar to move the LED to the desired preset level
according to the Fade Rate Chart. By tapping the TOP of the Rocker
this setting will automatically be saved and the device will advance to
the next programming mode, B-3 LED Options.
FADE RATE CHART
LED
Fade ON
Fade OFF
1
0 seconds (instant)
0 seconds (instant)
2
0.5 seconds
0.5 seconds
3
1.5 seconds
1.5 seconds
4
3 seconds
3 seconds
5
6 seconds
6 seconds
6
10 seconds
10 seconds
7
25 seconds
25 seconds
B-3) The Locator LED will blink 3 times per second to indicate Program
Mode B-3, LED Options. To change the LED Options settings, use
the DIM/BRIGHT Bar to move the LED to the desired preset setting
according to the LED Options Chart. By tapping the Top of the
Rocker this setting will automatically be saved and the device will exit
Programming Mode B.
LED OPTIONS CHART
LED
Locator LED Timeout
LED Brightness Display Options
1
Active
Active
2
Active
Turns OFF 5 seconds after use
3
Turns OFF 5 seconds after use
Active
4
Turns OFF 5 seconds after use
Turns OFF 5 seconds after use
5
N/A
N/A
6
N/A
N/A
7
N/A
N/A
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
CONTROLLING YOUR DIMMER WITH BLUETOOTH
®
Download the Leviton Decora
®
Digital Dimmer & Timer App for
your device.
Android: Tap the Google Play Store icon on your phone or go to
http://play.google.com on your computer and follow the
instructions to obtain the app.
iPhone: Tap the App Store icon on your phone or access the app
through your iTunes account on your computer.
Once you have downloaded the app, follow the instructions on the screen
to pair your mobile device with your dimmer. Once your mobile device is
paired, use the following options to control your dimmer:
• On - Off: Turns the dimmer ON and OFF.
• Schedule: Creates distinct ON/OFF events based on time and day.
• Sleep Timer: Sets countdown to turn dimmer OFF.
Advanced Settings
Device Options
• Randomized Scheduled Events: Cycles lights ON and OFF to
ensure a "lived-in" look while away.
• Hide LED Dim Bar: Turns LED Dim Bar OFF.
• Hide Status LED: Turns Status LED OFF.
• DST Offset Hours: Adjusts the Sunrise/Sunset time in hours.
• DST Offset Minutes: Adjusts the Sunrise/Sunset time in minutes.
Bulb Options
• Load Type: Sets load type to Electronic Low Voltage, Incandescent,
LED or CFL.
• Fade On: Sets the amount of time for the lights to turn ON to
maximum brightness.
• Fade Off: Sets the amount of time for the lights to turn to OFF from
maximum brightness.
Lighting Options
• Preset: Sets the brightness level at which the lights turn ON.
• Minimum: Sets a minimum brightness level for lighting.
• Maximum: Sets a maximum brightness level for lighting.
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a
Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment OFF and ON, the user is
encouraged to try to correct the interference by one or more of the following
measures:
•
Reorient or relocate the receiving Antenna.
•
Increase the separation between the equipment and the receiver.
•
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•
Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modiications not expressly approved by Leviton Manufacturing
Co., Inc., could void the user's authority to operate the equipment.
TROUBLESHOOTING
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured irmly with wire connectors of dimmer or
terminal screws of remote.
- If using in a dimmable luorescent application see Advanced
Programming Feature A-1.
• Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Neutral not wired to Dimmer (White wire).
- Conirm that the device is being supplied from a 120V, 60 Hz AC
source ONLY.
• I ntermittent dimmer operation
- Conirm that the Load being controlled does not exceed the
1000VA dimmer limit.
• Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
- Ensure wiring is correct.
FACTORY DEFAULT
If your dimmer is not responding, or you are unable to control it after
you have tried to Pair/Connect to it multiple times, it may be necessary
to reset the dimmer to its original factory settings. To accomplish this,
proceed as follows:
On the dimmer, hold the TOP of the rocker until the locator LED starts
to blink. The dimmer is now reset. Once the dimmer is reset, it may be
necessary to re-pair with the your application.
For additional information, contact Leviton's Techline at
1-800-824-3005 or visit Leviton's website at www.leviton.com
This product is covered by U.S. Patent No. 8,664,886 and corresponding
foreign patents.
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired
operation of the device.
Copyright and Trademark Information
The Bluetooth
®
word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc., used under license by Leviton.
Use herein of third party trademarks, service marks, trade names, brand
names and/or product names are for informational purposes only, are/may
be the trademarks of their respective owners; such use is not meant to imply
afiliation, sponsorship, or endorsement.
No part of this document may be reproduced, transmitted or transcribed
without the express written permission of Leviton Manufacturing Co., Inc.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada
should contact Leviton in writing at Leviton Manufacturing of Canada
Ltd to the attention of the Quality Assurance Department, 165
Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by
telephone at 1-800-405-5320.
© 2015 Leviton Mfg. Co., Inc.
DI-000-DDE06-02A-X0