WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
• TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor- or a transformer-operated appliance.
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are unsure about any part of these instructions, consult an electrician.
• Use with magnetic low voltage transformers, incandescent, or 120V halogen ixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.
• The Decora
®
DDE06 dimmer is not compatible with standard 3-way or 4-way switches. It must be used with a Decora
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
INTRODUCTION
The next generation of lighting control technology is here with the new
Decora
®
Digital Dimmer with Bluetooth
®
Technology. This innovative
device works using the Leviton Decora
Digital Dimmer & Timer app
®
that can be easily downloaded to smartphones or tablets and paired
to the Leviton Dimmer using Bluetooth
®
technology. Decora
®
Digital
Devices give users point-to-point local control to automate lighting,
bridging the gap between standard dimmers and whole-house
automation systems.
The Decora
®
Digital Dimmer is a powerful device – combining the best
of Leviton dimmer and timer functions with today's mobile technology
for impressive results. The simple touch of a inger following the
intuitive on-screen guide makes it more convenient than ever to
manage lighting for home activities or to ensure a "lived-in" look while
away. Plus, the Decora
Digital Dimmer is Universal and compatible
®
with LED, CFL, Incandescent or Halogen loads.
Use of the app allows greater lexibility for accurate timer functionality
and makes pushing buttons for timed events a tedious chore of the
past.
The Leviton Decora
®
Digital Dimmer & Timer app can be easily
downloaded to mobile devices and is compatible with Android and iOS
smartphones or tablets. The app is easy to use with simple, intuitive
on-screen menu options to independently control dimmers and
switches throughout the home.
Decora
®
Digital Devices are ideal for living rooms, bedrooms, kitchens,
dining rooms, home ofices, outdoor lighting or anywhere full control of
lighting is desired.
Compatibility:
Requires device with Bluetooth
4.0 (BT LE) or later and iOS 6.0 and
®
later. Compatible with iPhone, iPad, and iPod touch or Android 4.0 and
later.
FEATURES
• Soft fade ON/OFF
• ON/OFF LED and Brightness level LED
• Three way communication
• Ease of installation – No new wiring
TOOLS NEEDED TO INSTALL YOUR DIMMER
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Changing the color of your Dimmer:
Your device may include color options. To change color of the face
proceed as follows:
1
2
Push in sides at bottom
Insert top tabs and
tabs and pull outward to
press in bottom tabs
release
to attach
INSTALLING DIMMER BY ITSELF
OR WITH OTHER DEVICES
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a
multi-device application, proceed as follows:
Single Pole (One location) or 3-Way (Multi-location)
Cat. No. DDE06-BL - 600W Incandescent, 300W LED/CFL, 600W ELV
®
Digital remote for multi-location control, such as the DD00R-DL.
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the reduction of the dimmer's capacity may
be required. Refer to the chart for maximum load per dimmer.
NOTE: No derating is required for LED or CFL bulb applications.
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Single
Two Devices
More than 2 Devices
600W
500W
400W
MAXIMUM BULB WATTAGE
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage
is determined by the eficiency of the transformer in the low-voltage lighting
system. Transformer eficiencies will vary from different manufacturers;
consider 80% eficient as average. Use the chart to determine maximum bulb
wattage for typical transformer eficiency ratings.
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
Rating
Single
Two Gang
More than 2 Gang
1000VA
800W
640W
560W
INSTALLING YOUR DIMMER
NOTE: Use check boxes
when Steps are completed.
WARNING:
Step 1
TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power
is off before wiring!
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Identifying your wiring application (most common):
Step 2
NOTE: If the wiring in your wall box does not resemble any
of these conigurations, consult an electrician.
1
2
2
1
3
3
4
5
4
3-Way
Single Pole
1. Line or Load
1. Line (Hot)
(see important
2. Neutral
instruction)
3. Ground
2. Neutral
4. Load
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
LED / CFL / Electronic Low Voltage Dimmer
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-3/4".
• Use this device WITH COPPER OR COPPER CLAD WIRE ONLY.
• Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen ixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.
• When multiple bulbs are used with one dimmer DO NOT mix bulb types. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance
dimmer performance.
INSTALLING YOUR DIMMER
NOTE: Use check boxes
when Steps are completed.
WARNING:
TO AVOID FIRE SHOCK OR DEATH; TURN
Step 1
OFF POWER at circuit breaker or fuse and test that power
is off before wiring!
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Identifying your wiring application (most common):
Step 2
NOTE: If the wiring in your wall box does not resemble any
of these conigurations, consult an electrician.
1
2
2
1
3
3
4
5
4
3-Way
Single Pole
1. Line or Load
1. Line (Hot)
(see important
2. Neutral
instruction)
3. Ground
2. Neutral
4. Load
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
IMPORTANT: For 3-Way applications, note that one of the screw terminals
from the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the dimmer wall box and remote wall box.
Preparing and connecting wires:
Step 3
Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are straight (cut if
necessary). Remove insulation from each wire in the wall box
as shown:
5/8"
Strip Gage
(1.6 cm)
(measure bare
wire here)
Cut
(if necessary)
• Pull off pre-cut insulation from dimmer leads.
• Make sure that the ends of the wires from the wall box are straight
(cut if necessary).
• Remove insulation from each wire in the wall box as shown.
• For Single-Pole Application, go to Step 4a.
• For 3-Way Matching Remote (w/LEDs) Application, go to Step
4b.
For non-standard wiring applications, refer
to Wire Nut and Connector Size Chart
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
Single Pole Wiring Application:
Step 4a
Black
1
White
2
4
Red
3
Green
Yellow/Red
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove insulating label.
Dimmer
Black
Hot (Black)
Red
Electronic
Low Voltage
White
Transformer
Yellow/Red
Black
Line
Primary
Green
120 VAC,
Side
Insulating
Ground
White
60Hz
Label
Neutral (White)
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING:
CONNECT AN ELECTRONIC LOW-VOLTAGE DIMMER
ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC
LOW-VOLTAGE TRANSFORMER.
NOTE: The DDE06 dimmer requires a neutral wire connection.
• Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot wall box wire to Black dimmer lead.
• Load wall box wire to Red dimmer lead.
• Line Neutral wall box wire to White dimmer lead.
• Yellow/Red dimmer lead should have Red insulation label afixed.
NOTE: If insulating label is not afixed to Yellow/Red dimmer lead, use
electrical tape to cover.
• Proceed to Step 5.
DI-000-DDE06-02A-X0
3-Way Wiring with DD00R Matching Remote
Step 4b
(w/LEDs) Application:
Matching Remote
Dimmer
Additional Neutral Wire
Black
4
2
White
2
1
1
Red
4
3
3
5
Green
5
Yellow/Red
Matching Remote (w/LEDs)
Dimmer
Hot (Black)
Black
WH
BK
Electronic
Red
Low Voltage
Green
Green
Transformer
Ground
Ground
White
Black
Yellow/
YL/RD
Primary
Line
Red
Side
120VAC, 60Hz
White
Neutral (White)
WIRING MATCHING REMOTE (wall box with line hot
connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The matching remote must be installed in a wall box with a
Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identiied (tagged) when removing
old switch and First Traveler to Remote terminal marked "BK".
• Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote
must go to Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The DDE06 dimmer must be installed in a wall box that has a
Load connection and a Neutral connection.
• Green or bare copper wire in wall box to Green dimmer lead.
• Load wall box wire identiied (tagged) when removing old switch to
Red dimmer lead.
• First Traveler Line Hot to Black dimmer lead.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to
Yellow/Red dimmer lead. This traveler from the dimmer must go to
the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White dimmer lead.
• Proceed to Step 5.

Publicité