FITTINGS INSTRUCTIONS
OPERATED
Manualy
Cable
Pneumatic
Options :
-
With a remote control system in cabin with inductil detector (report to the specific leaflet)
-
With back up camera (see specific leaflet)
ASSEMBLY CONDITIONS
•Check the compatibility of the loads in accordance with the following table (calculation method: report to the
catalogue).
• Ensure that the cross member is suitable to take the required loads
• Check the thickness of the cross member (see page 9).
TYPE
G150
G145
•Installing the coupling:
o According to the drilling drawing on page 9, using the hardware included.
o Offer up the product to the cross member without disassembling it.
• Tighten the screws with a torque wrench (see page 9)
o Pretighten the screws to 150 Nm in the order of the indicated callout items.
o Then secure to specified torque load.
• Installing the play comparation unit (Air confort) : tighten the screws to the torque mentioned page 9.
TYPE
AirConfort
Réf : 2907640FT-FR/EN/ES N° Ordre 110/1–Fait par : FA–Vérifié par : T.P–Date : 17/08/2017
Société par Actions Simplifiée au capital de 2 000 000 € – R.C.S. PONTOISE B 718 203 623 – C.C.P. PARIS 4789-04 D – SIREN 718203623 – APE 503-A
Handle
With
Ramp
R
R/L
L
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Perçages
D (kN)
160 x 100
200
140 x 80
120
G150
With Play
compensation
G150
2907640
2907640L
2907641
X
2907642
X
2907642L
X
2907643
2907644
2907644L
X
2907646
X
2907646L
X
2907642C
X
2907642P
Dc (kN)
S (kg)
160
1000
95
1000
3
Install the Air
confort
TYPE
G145
2907650
2907650L
2907651
2907652
2907652L
2907653
2907654
2907654L
2907656
2907656L
2907652C
2907652P
V (kN)
140
36
G145
1 Install the spacer
8/19