Item number
Line Output
Connector
Maximum output level
3rd Party Control
Connector
Main volume (VCA)
Power Supply
Type
Voltage range
Power supply plugs
Power supply secondary
Max power consumption
Idle power consumption
Max. standby power consumption
General
Housing material
Front panel material
Dimensions (W x H x D)
Rack height
Rack width
Weight
Operating temperature
Max. operating humidity
(non condensing)
Included accessories
Optional accessories
LDPRE2
3-pin Terminal block, pitch 3.81mm
16 dBu
3-pin Terminal block,pitch 3.5mm
10k (Linear Taper) External Potentiometer
External SMPS
100 VAC – 240 VAC (±10%), 50 – 60 Hz
Type C – EU,
Type A – USA/Canada,
Type G – UK
Type I – Australia
24 VDC / 500 mA
6 W
5 W
0.4 W
Steel
Plastic
106 x 54 x 227 mm (height with rubber feet)
1 RU
1/4 19"
0.8 kg
0°C – 40°C
85%
External power supply with interchangeable plugs,
Mounting plates for surface mount applications
Rack mounting hardware (LDTICARK)
15