INSTALLATION OPTIONS
Read this entire manual before you install and use your
pellet stove.
Failure to follow instructions may result in
property damage, bodily injury, or even death!
(See specific installation details for clearances and other
installation requirements)
A Freestanding Unit—supported by pedestal/legs and
placed on a non-combustible floor surface in compliance
with clearance requirements for a freestanding stove
installation.
Your pellet stove may be installed to code in either a
conventional or mobile home (see SPECIAL MOBILE HOME
REQUIREMENTS). The installation must comply with the
Manufactured Home and Safety Standard (HUD), CFR3280,
Part 24.
It is recommended that only a authorized technician install
your pellet stove, preferably an NFI certified specialist.
DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM.
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty.
IMPROPER INSTALLATION: The manufacturer will not be held
responsible for damage caused by the malfunction of a
stove due to improper venting or installation. Call (800) 750-
2723 and/or consult a professional installer if you have any
questions.
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home
clearances given below. For safety reasons, please adhere
to the installation clearances and restrictions. Any reduction
in clearance to combustibles may only be done by means
approved by a regulatory authority.
FLOOR PROTECTION
This heater must have a non-combustible floor protector
(UL1618 ember protection) installed beneath it if the floor is
of combustible material. US: Floor protector should be UL
listed or equal too, needs to extend 6" to the front, 6" to
each side, 1" to the rear of the unit. Under and 2" beyond
each side of the cleanout tee if an interior vertical instillation.
Canada: Floor protector should comply with CAN/
ULC standards. Needs to extend 18" to the front, 8" beyond
each side of the unit.
K
K
L
L
L
M
M
P
P
THROUGH THE WALL
INSTALLATION
4
Installation
in accordance with the
O
O
L
INTERIOR VERTICAL
INSTALLATION
A
Side Wall to Stove
B
Side Wall to Vent Pipe
C
Back Wall to Stove
D
Back Wall to Vent Pipe
E
Ceiling to Floor
F
Ceiling to Stove
CORNER CLEARANCES
G
Side Wall to Stove
H
Side Wall to Vent Pipe
I
Back Wall to Stove
J
Back Wall to Vent Pipe
F
E
FLOOR PROTECTOR CLEARANCES
K
Back to Stove
N
N
L
Side to Stove
M
Front to Stove
N
Back to Flue
O
Overall Length
P
Overall Width
CLEARANCES
10 in (254 mm)
11.5 in (292 mm)
11.875 in (302 mm)
3 in (76 mm)
84 in (2134 mm)
53.875 in (1434 mm)
7.5 in (191 mm)
11.25 in (286 mm)
7.5 in (191 mm)
3 in (76 mm)
ADJACENT WALL
G
H
D
C
U.S. 1 in (26 mm)
Canada 8 in (204 mm)
U.S. 6 in (153 mm)
Canada 8 in (204mm)
U.S. 6 in (153 mm)
Canada 8 in (204 mm)
2 in (51 mm)
31 in (788 mm)
38 in (966 mm)
J
I
B
A