Converting Appliance for Use with LP Gas
WARNING
Conversion is to be performed by a AUTHORIZED
SERVICER (or other qualified agency) in accordance
with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to
follow instructions could result in serious injury or property
damage.
The qualified agency performing this work assumes
responsibility for this conversion.
WARNING
Before proceeding with the conversion, shut off the gas
supply to the appliance prior to disconnecting the electrical
power
If this appliance should be converted for use with gas
LP (propane or butane), each of the following modification
must be performed:
Gas conversion label (aluminium) to be placed on the back
of the appliance, near the data plate, after conversion has
been carried out;
Replace injector on (one ring flame burners)
1. Remove the grates and burner cups.
2. Remove aluminum gas spreader.
3. Loosen injector by turning 9-32" (7 mm) nut driver counter
clockwise.
4. Install the injectors supplied with this appliances in the
appropriate burner. The injectors have small number
stamped on the side, this number codes the orifice
diameter and its correct burner location (see figure on
page 17).
5. Turn clockwise to tighten (tighten to a torque of 15 to 20
inch-lbs).
6. Replace all parts following the reverse order.
7. Save the orifices removed from the appliance for future
use.
6 - Conversion for LP or NG Gas
Replace injectors on (two rings flame burner)
1. Remove the grates and burner cups.
2. Remove aluminium gas spreader.
3. Remove the three screws of simmer gas spreader (1).
4. Remove the two screws of injector cover (2).
5. Loosen injector (A) by turning 9-32" (7 mm) nut driver
counter clockwise.
6. Loosen injector (B) by turning 9-32" (7 mm) box wrench
counter clockwise.
7. Install the injectors supplied with this appliances in the
appropriate burner. The injectors have small number
stamped on the side, this number codes the orifice
diameter and its correct burner location (see figure of
the paragraph "Injectors position").
8. Turn clockwise to tighten (tighten to a torque of 15 to 20
inch-lbs).
9. Replace all parts following the reverse order.
10. Save the injectors removed from the appliances for
future use.
After injectors replacement adjust the burner flame (see Low
Flame Adjustment paragraph).
Check the appearance of each burner's flame at HILO
settings, if the flame appear too large or too small make
sure that all steps were completed correctly.
Convert the pressure regulator on LP position following the
illustration.
EN