8. Programming the fitting
8. Programming the fitting
Programme the fitting before installation. You can use
different programming devices, depending on the
product family.
14
15
16
9. Installing the fitting
Door pre-drilled.
ü
PH2 screwdriver at hand.
ü
TX15 screwdriver at hand.
ü
1. Insert the supplied blind rivet nuts into the door
frame.
17
2. Screw the mounting plate firmly into place on the
outside so that the spring clips are facing the door
(PH2, torque 1.1 Nm).
18
3. Screw the escutcheon base firmly to the outside
(PH2, torque 1.1 Nm).
19
4. Screw the escutcheon base firmly into place on the
inside (PH2, torque 1.1 Nm).
5. Insert the fitting into the mounts on the mounting
plate.
20
6. Push the fitting into the mounting plate until it locks
into position.
21
7. Screw the fitting firmly to the mounting plate (PH1,
torque 0.8 Nm).
22
8. Place a cover with the notch facing downwards on
the escutcheon base.
23
9. Place the cover on the fitting.
24
10. Fit the outside handle into position on the fitting.
25
11. Determine the required direction of rotation for your
inner handle.
12. Insert the spring element appropriately.
48 / 92
Digital SmartHandle AX Metal frame
13. Place the underlay in the inner handle unit.
26
27
14. For 8.5 mm and 10 mm spindle: slide the adapter
sleeve into the centre of the spindle. Use a punch
and hammer to make an indent in the adapter
sleeve to prevent it from slipping.
28
29
15. Measure the total length of the spindle.
30
16. Locate the inside of the spindle (four-edge end up
to the centre of the first groove = 26 mm).
17. Use the table to determine the position of the O-
ring.
31
EN