Characteristics
• Power supplied by two LR03 or AAA-type 1.5 V
alkaline batteries (supplied), autonomy greater than
2 years for normal use,
• Class III insulation
• On/Off regulation,
• Built-in proportional control, time basis 15 min.,
• 868 MHz transmission frequency, class I (standard
EN 300 220)
• Radio remote control device
• Radio range 100 to 300 metres outside varies
depending on the equipment associated (the range
can be altered depending on the installation conditions
and the electromagnetic environment)
• Dimensions: 135 x 81 x 0.87 in
• Protection index: IP 30
• Wall mounting or on flush-mounted box
• Installation in an environment with normal pollution
levels
• Storage temperature: -10°C to +70°C
• Operating temperature: 0°C to +40°C
- 38 -
Help
The purpose of this section is to help you quickly solve the
most common problems that you may encounter with your
product during use.
If you're unsure, or if the problem persists or isn't in this list,
contact your installer.
Nothing is displayed on the room unit screen.
There is no power supply.
Check the batteries (and their polarity).
The temperature displayed does not match the
temperature measured in the room (thermometer).
Refer to the CFO1 menu in the start-up operation.
Your heating/air-conditioning system is off.
The selector knob is still on
another position.
The screen displays 4 dashes"- - - -". The unit is off.
3 possibilities:
- the absence function is set in COOL mode,
- the Economy temperature is not regulated in COOL mode
(CF04 menu, start-up)
- Frost Protection mode is set and the change-over input of the
heat pump is not controlled by the thermostat (CF06 menu,
start-up).
The receiver does not accept orders from the
transmitter.
Repeat a radio test, move the transmitter or associate
the devices again.
, PROG or
. Turn the knob to
- 39 -