Télécharger Imprimer la page

ARTHUR MARTIN AGS6404K Notice D'utilisation page 7

Publicité

Les langues disponibles

Les langues disponibles

Make sure that the gas supply
pressure of the appliance
obeys the recommended
values. The adjustable
connection is fixed to the
comprehensive ramp by means
of a threaded nut G 1/2". Screw
the parts without force, adjust
the connection in the
necessary direction and tighten
everything.
A
A. End of shaft with nut
B. Washer supplied with the appliance
C. Elbow supplied with the appliance
Liquid gas
Use the rubber pipe holder for liquid gas.
Always engage the gasket. Then continue
with the gas connection.
The flexible pipe is prepared for apply
when:
• it can not get hot more than room
temperature, higher than 30°C;
• it is no longer than 1500 mm;
• it shows no throttles;
• it is not subject to traction or torsion;
• it does not get in touch with cutting
edges or corners;
• it can be easily examined in order to
make sure its condition.
The control of preservation of the flexible
pipe consists in checking that:
• it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
• the material is not hardened, but shows
its correct elasticity;
• the fastening clamps are not rusted;
• expired term is not due.
B C
If one or more defects are visible, do not
repair the pipe, but replace it.
WARNING! When installation
is complete, make sure that the
seal of each pipe fitting is
correct. Use a soapy solution,
not a flame!
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the type
of gas you use (see table in "Technical
Data" chapter).
4. Assemble the parts, follow the same
procedure backwards.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure
adjuster on the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob and the gasket.
7

Publicité

loading

Ce manuel est également adapté pour:

Ags6404sx