Setting Up The Pneumatic Motor En - Abicor Binzel BRS-CC Mode D'emploi

Masquer les pouces Voir aussi pour BRS-CC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BRS-CC
6.9 Setting up the pneumatic motor
8
7
6
1
Gas nozzle
2
Clamping device
Fig. 13
Setting up the pneumatic motor
1 Loosen the motor clamp via the set screws (7) and the cylinder head screws (5) on the guide block (8).
2 Pull back the pneumatic motor (6) in its mount.
3 Place the required distance sleeve (3) on the reamer (4).
4 Move the torch with the gas nozzle (1) to the clamping position (C).
5 Keep the guide block (8) in the lower position (stroke down).
6 Place the pneumatic motor (6) against the gas nozzle (1) with the distance sleeve (3) placed on top.
7 Secure the adjusted motor position with the cylinder head screws (5) and set screws (7). (Tightening torque 3.4 Nm)
8 Move the torch out of the clamping device (2) and remove the distance sleeve (3) from the reamer (4).
NOTICE
• Make sure that only clean and dry compressed air is used.
The compressed air must correspond at least to the quality class 4 according to ISO 8573-1.
BAL.0109 • 2020-12-15
C
1
2
3
4
5
3
Distance sleeve
4
Reamer
5
Cylinder head screws
7
6
Pneumatic motor
8
6 Commissioning
Set screws
Guide block
EN - 21

Publicité

Table des Matières
loading

Table des Matières