Automatic Heat Up time function
The purpose of the Automatic Heat-Up time function is to automate raising food to the desired
temperature more quickly compared to simply setting the inductor to that setting.
Automatic Heat-Up function will act as a 'fast preheat' for an inductor. It will apply setting 9 wattage
in order to achieve your desired lower set temperature more quickly.
It is not recommended to use this function to preheat an empty pot or pan.
Example: you set an inductor to setting 4. It receives a set amount of wattage that is maintained
consistently throughout the setting. However, at that wattage it would take quite a bit of time to reach
temperature due to the lower wattage input. If you set the inductor at 9 it receives a great deal more
wattage which raises the temperature more quickly. How to you get to the temperature of setting 4 but
reach it with the speed and wattage of setting 9? Enter Automatic Heat-Up function.
To activate the Automatic Heat-Up time function, press and turn the knob counterclockwise to position
"A" on the knob (you will feel a spring-back resistance). Hold it on "A" until the "A" symbol shows on
the display of the inductor you are adjusting. It will blink waiting for the next input. Within 10 seconds
(while the "A" is flashing) select your desired cooking level from 1 through 8. This function will not work
if you set it to melt, keep warm or level 9 after the "A" starts flashing.
This will be the cooking level after the automatic heat-up is complete. During the automatic heat-up
period, the inductor's display will alternate between "A" and the selected cooking level. Refer to the
table below for the time that Automatic Heat-Up mode will operate at setting 9 before automatically
switching to the actual level set.
Once the Automatic Heat-Up function is locked in any adjustment to the knob will cancel the mode and
the inductor will simply operate at the set temperature. So, if you feel that the power 9 has run long
enough, you can easily cancel the mode by rotating the knob to a new a different setting and back to
your original setting if so desired.
Automatic heat-up
Level Zone
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Time (seconds)
48
144
230
312
408
120
168
216
-
EN