C-3
14
15
16
12
17
Place volume handle (11) onto cartridge.
Seat stop (13) into volume handle, place
adapter (14) into handle and tighten screw
(15). Thread cover (12) onto handle. Place
temperature handle assembly (16) onto
cartridge and drive set screw (17).
C-4
1
3
Install adapter (1) over valve stem (2) and secure it with screw (3).
Install washer (4) onto handle (5), slide handle onto adapter and secure it with screw (6), then
cover set screw with handle button (7).
6
Potential scald or thermal shock injury could result due to cross flow if outlet at the
shower is blocked or restricted (e.g., pause control on hand shower). Be sure to point
hand shower away from you when re-starting flow or install inlet check valves on both
supply lines to prevent possible injury.
13
11
2
6
11
4
5
7
107529 Rev. E

Publicité