TROUBLESHOOTING GUIDE
SYMPTOMS
Motor does not start or
shuts down
Overheating
No power present
Machine noisy
Circuit breaker is tripped
MAINTENANCE REPAIRS
If maintenance or repairs are required, contact one of our approved agents. For quick and
effective service, your agent will need to know the model, type and code numbers of your
generator set.
118025-4-Manual-F.indd 35
PROBABLE CAUSES
1- Generator set placed on load during start-
up.
2-Petrol or oil dipstick too low.*
3- Start-up control set to «OFF»
4- Fuel cock closed*
5- Fuel system blocked or leaky*
6- Air filter blocked
1- Ventilation opening blocked
2- Probable overload
1- Circuit breaker tripped
2- Defective circuit breaker
3- Defective female connector.
4- Defective equipment power cable
5- Defective AC generator.
1- Ball bearing broken
1- Defective exhaust
1- Generator set overload
2- Defective equipment or cable
© FAR GROUP EUROPE
CORRECTIVE ACTIONS
1- Remove load
2- Fill with petrol or oil
3- Set control to «ON»
4- Open cock
5- Return system to operational condition
6- Clean air filter
Clean intake and exhaust protectors
2- Check load
1- Switch on circuit breakers
2- Have checked, repaired or replaced
3- Have checked, repaired or replaced
4- Replace cable
5- Have checked, repaired or replaced
1- Inspect and replace
2- Inspect and replace
1- Reduce load
2- Have checked, repaired or replaced
EN