Charging
Your Pro-User IBC charger can easily be configured to charge many different types of batteries.
The
following recommendations should, however, only be seen as guidelines. When in doubt, always consult
the battery manufacturer for further instructions.
Starting the charging process:
1. Once you have established that the battery clamps or eyelets have been correctly
connected, you can start the charging process. To do so, insert the charger plug into the AC
socket.
2. The charger will start in Standby mode, indicated by the STAND BY LED.
3. Press the mode button to select the appropriate charge mode (press and hold for three
seconds to enter an enhanced charge mode) for the voltage and chemistry of your battery.
The selected charge mode LED will illuminate.
Charging Modes.
The IBC15000B has nine (9) modes. The Lithium and Recover charge modes require the mode button
to be pressed and held for three (3) seconds to enter the enhanced mode. These "Enhanced" modes
require your full attention before selecting.
NEVER USE RECOVER MODE ON LITHIUM IRON PHOSHATE BATTERIES .
Do not operate the charger until you confirm the appropriate charge mode for your battery.
Below is a brief description:
For charging 12-volt batteries in cold temperatures below 50°F (10°C) or AGM batteries. When selected,
For charging 24 volt batteries in cold temperatures below 50°F (10°C) or AGM batteries. When selected,
Charging Modes
For charging 12-volt Flooded, Gel, Maintenance-Free batteries.
14.5V
14.7V
For charging 24-volt Flooded, Gel, Maintenance-Free batteries. When selected, the LCD will illuminate.
29V
29.4V
For charging 12 volt advanced AGM batteries that require a higher than normal charge voltage. When
15V
For recovering and repairing and storing, old, idle, damaged stratified or sulfated Flooded, Gel,
Maintenance-Free Lead Acid batteries. When selected, the LCD will illuminate.
NEVER USE RECOVER MODE ON LITHIUM BATTERIES
14.7V
For charging 12.8-volt lithium iron phosphate batteries. When selected, the LCD will illuminate.
14.5V
Converts to a DC power supply for powering any 12V DC device. When selected, 13.6V LCD will
2.6A, 270 seconds; then 20A, 30 seconds. That means the charger charges the battery 270 seconds on the
first part to warmup the battery, then charges it 30 seconds with extremely high current to "bump' up the
battery. After that the charger will go to standby status and can be charged in a normal way.
12V NORM
15A
12V COLD/AGM
the LCD will illuminate.
15A
24V NORM
7.5A
24V COLD/AGM
the LCD will illuminate.
7.5A
12V AGM+
selected, the LCD will illuminate.
15A
12V RECOVER
Press & Hold Mode
2.6A
12.8V LITHIUM
Press & Hold Mode
15A
13.6V Power Supply
illuminate
JUMP CHARGE = Boost Charge
50-400Ah Batteries
50-400Ah Batteries
25-200Ah Batteries
25-200Ah Batteries
50-400Ah Batteries
50-400Ah Batteries
30-200Ah Batteries