Télécharger Imprimer la page

V2 CITY2+120V Mode D'emploi page 38

Armoire de commande numerique pour portails a vantails et coulissants

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
12 - CONTROL UNIT CONFIGURATION
Control unit time and function programming is made within a special
configuration menu, to which you can access and where you can shift
through DOWN, MENU and UP keys placed under the display.
Hold down the MENU key until
programming mode while display views the panel.
The configuration menu consists in a list of configurable items; the display
shows the selected item.
• By pressing DOWN, you will pass to the next item
• By pressing UP, you will return to the previous item
• By pressing MENU, you can view the current value of selected item and
possibly change it.
FinE
The last menu item (
) allows storing the carried out changes and going
back to the control unit normal operation.
You must exit from programming mode through this menu item if you do not
want to lose your configuration.
m
WARNING: in case no operation is carried out for more than one
minute, the control unit exits from the programming mode without
saving any of your setups and changes, which will get lost.
NOTE: By holding down the UP or DOWN keys, configuration menu items will
FinE
scroll fast, until item
is viewed. In this way, you can quickly reach either
the top or bottom of the list.
PARAMETER
VALUE
En.SA
no
Si
t.AP1
0.0"-5'00
t.AP2
0.0"-5'00
-PrG
appears on display, to activate the
DESCRIPTION
ENERGY SAVING function
This function is useful for reducing the energy consumption of the
automation device while in stand-by mode.
If the function is enabled, the control unit will enter ENERGY SAVING
mode under the following conditions:
• 30 seconds after completion of an operational cycle
• 30 seconds after an opening (if automatic closure is not enabled)
• 30 seconds after exiting the programming menu
In ENERGY SAVING mode, power to the accessories, display, flashing lights
and closure electromagnets is deactivated.
ENERGY SAVING mode is exited:
• If an operational cycle is activated
• If one of the keys on the control unit are pressed
NOTE: during battery powered operation, if the level of charge is
insufficient to activate the automation device (the display shows
Err0), the ENERGY SAVING function is activated automatically in
order to reduce power consumption while awaiting mains power
to be restored.
Function deactivated
Function activated
Leaf 1 opening time
Adjustable time from 0 seconds to 5 minutes
Leaf 2 opening time
Adjustable time from 0 seconds to 5 minutes.
WARNING: if motor 2 is not connected, this time must be set to
zero
CITY2+
CITY2+L
CITY2+BC
- 36 -
DOWN MENU
UP
OVERLOAD
DEFAULT
MEMO
no
22.5"
22.5"
MAINS

Publicité

loading

Ce manuel est également adapté pour:

City2+lCity2+City2+bc12a042