EFE400M Instruction Manual
Input Parameters
Standard
Nominal input voltage
Input voltage range
Input frequency range
Maximum input current
* Input de-rated, see variations and limitations below.
** Dc input ratings applicable to IEC/EN/UL/CSA60950-1& 62368-1, specific Non-standard versions only.
All ratings apply for ambient temperatures up to 50°C. (See variations and limitations below)
Output Parameters
There are three EFE400M standard models and two non-standard models with various options and output
parameters shown in the tables below.
Standard models:
Standard model:
Output Channel
Channel 1
Fan output
Standby output
Variations and limitations of use for Standard models:
1. Output power de-rated 1% per volt from 100V to 90V input (channel 1 power 360W at 90V input).
2. Maximum ambient 70°C (de-rating output power 2.5% per °C above 50°C).
3. * Can be adjusted at the factory only.
4. Maximum continuous power output 400W (including fan output).
5. † Models with a combination of (i) vertical output connector), (ii) ORing FET and (iii) case with fan, are limited to
400W max at 40°C ambient or 350W at 50°C ambient.
6. ** Peak power for 10 seconds maximum, maximum rms power of 400W:
400
Wrms
(
peakpower
where T1 = peakpower time on
and
T2 = reducedpower time on
Non-Standard Models:
Non- Standard model: Y60001# (# can be any letter) (EFE400M-48-5-BCSDL-
NT)
Output Channel
Channel 1
Standby output
Additional variations and limitations of use for Non- Standard model Y60001#:
1. Maximum ambient 50°C.
2. * Can be adjusted at the factory only.
Non- Standard model: Y60002# (# can be any letter) (EFE400M-12-5-NNMDL-
NE-V)
Output Channel
Channel 1
Standby output
Additional variations and limitations of use for Non- Standard model Y60002#:
1. Output power de-rated from 450W to 410W from 100V to 90V input. (e.g. channel 1 power 410W at 90V input)
2. IEC/EN60950-1 & 62368-1only.
3. Maximum ambient 40°C.
4. * Can be adjusted at the factory only.
60601-1
100 - 240 Vac
90 - 264Vac*
45 - 63Hz
6.1A rms
Vout Nom.
Adjustment
Range (V)
12
11.4 - 13.2*
24
22.8 - 26.4*
48
47 - 50*
12
12
5
5
12
12 - 12.2*
2
T
1
reducedpow
Vout Nom.
Adjustment
Range (V)
48
47 - 50*
5
Fixed
Adjustment
Vout Nom.
Range (V)
12
11.4 - 13.2*
5
Fixed
60950-1 & 62368-1
100 - 240 Vac
90 - 264Vac*
45 - 440Hz
6.1A rms
Output
Maximum
Current (A)
Power (W)
33.33
400† (530**)
16.67
400 (530**)
8.33
400 (470**)
1
12
2
10
1
12.2
2
er
T
) 2
/(
T
1
T
) 2
Output
Maximum
Current (A)
Power (W)
8.33
400
2
10
Output
Maximum
Current (A)
Power (W)
37.5
450 (530**)
2
10
Page 16 of 27
60950-1 & 62368-1
133 - 318 Vdc**
120 - 350Vdc**
DC**
5A
23198 issue 19, February 2022