Télécharger Imprimer la page

ETNA KGF875RVSA Mode D'emploi page 13

Publicité

Les langues disponibles

Les langues disponibles

MALFUNCTIONS
SYMPTOM
Burner
extinguishes out
after igniting.
Where the GAD type examination certificates of KIWA refer to the appliance
category "I2EK" this is understood as:
This appliance was configured for the appliance category K (I2K) and is suitable for
the use of G and G+ distribution gases according to the specifications as included in
the NTA 8837:2012 Annex D with a Wobbe index of 43.46 – 45.3 MJ/m3 (dry, 0 °C,
upper value) or 41.23 – 42.98 (dry, 15 °C, upper value).
This appliance can moreover be converted and/or again be calibrated for the
appliance category E (I2E) This therefore implies that the appliance: "is suitable for
G+ gas and H gas or is demonstrably suitable for G+ gas and can demonstrably be
made suitable for H gas" within the meaning of the "Dutch Decree of 10 May 2016
regarding amendment of the Dutch Gas Appliances Decree...."
POSSIBLE CAUSE
You did not press the
control knob long and/or
deep enough (at least 3
seconds).
Thermocouple (3) is dirty.
SOLUTION
Keep the control knob fully pressed for
at least 3 seconds between high and low
settings. This can be longer the first time,
because of the supply of gas.
Clean/dry the thermocouple.
EN 7

Publicité

loading

Ce manuel est également adapté pour:

Kgf875ztaKgf889rvsaKgf889zta